Hyper-viscoelastic characterization of the urethra

Abstract Hyper-viscoelastic models have been used to characterize large strains coupled with viscosity. In this study, we aimed to model the urethral in-vivo biomechanics through a hyper-viscoelastic implementation. First, we used isotropic 2-parameter Demiray model for identification of urethral tube inflation after refining the values of quasistatic states. Attempting the approach by Holzapfel et. al., the average ratio of the elastic and dynamic modulus was computed to determine the stress contribution of the viscoelastic branches. The values of the parameters were determined after constraining a constant Energy dissipation (generalized maxwell) over range 1s to 100s. For the hyper-viscoelastic comparison implementation, it was observed that the goodness of fit criteria performs good for half of the samples (Adjusted R2>0.95). In some samples, the model is limited to fit ‘S’ shape curves but still performed well. The above identification technique and the hyper-viscoelastic in-silico approaches show that our approach fares sufficiently for the creep response characterization of the urethra.

Authors

Institutions

Publication Details

Journal
Current Directions in Biomedical Engineering
Published
2024-12-01
DOI
https://doi.org/10.1515/cdbme-2024-2020
Primary Topic
Urological Disorders and Treatments
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Hyper-viscoelastic characterization of the urethra

Jaya Joshi, Knut Möeller, Stefan J. Rupitsch, Ashish Bhave et al.
Current Directions in Biomedical Engineering
Urological Disorders and Treatments
article

Hyper-viscoelastic characterization of the urethra

Jaya Joshi, Knut Möeller, Stefan J. Rupitsch, Ashish Bhave, Vaishnavi Yache
article en

Abstract

Abstract Hyper-viscoelastic models have been used to characterize large strains coupled with viscosity. In this study, we aimed to model the urethral in-vivo biomechanics through a hyper-viscoelastic implementation. First, we used isotropic 2-parameter Demiray model for identification of urethral tube inflation after refining the values of quasistatic states. Attempting the approach by Holzapfel et. al., the average ratio of the elastic and dynamic modulus was computed to determine the stress contribution of the viscoelastic branches. The values of the parameters were determined after constraining a constant Energy dissipation (generalized maxwell) over range 1s to 100s. For the hyper-viscoelastic comparison implementation, it was observed that the goodness of fit criteria performs good for half of the samples (Adjusted R2>0.95). In some samples, the model is limited to fit ‘S’ shape curves but still performed well. The above identification technique and the hyper-viscoelastic in-silico approaches show that our approach fares sufficiently for the creep response characterization of the urethra.

Current Directions in Biomedical EngineeringVol. 10(4)
Furtwangen University (DE)
Openalex Percentile: Top 61%
Urological Disorders and Treatments
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.