Abstract Electrical Impedance Tomography is a noninvasive imaging technique that employs electrical currents to reveal the internal conductivity distribution within the body. The study follows a new Radio Frequency (RF) approach, by using a Vector Network Analyzer to provide a multifrequency measurement between 10 kHz and 1 GHz. A plastic and a metallic object were positioned within a saline-filled phantom to test the EIT reconstructed images at different frequencies. The results show that based on the image reconstruction, the material’s conductivity can be distinguished at specific frequencies. However, beyond 10 MHz, the reconstructed images become less reliable until reaching 1 GHz, where the reconstructed image deteriorates significantly. While Electrical Impedance Tomography (EIT) has potential in new applications, its efficacy is limited by the ill-posed problem of the reconstruction. Further development and refinement of techniques, particularly in addressing issues that occur at higher frequencies, are required to realize EIT’s full potential in various fields.

Authors

Institutions

Publication Details

Journal
Current Directions in Biomedical Engineering
Published
2024-12-01
DOI
https://doi.org/10.1515/cdbme-2024-2088
Citations
1
Primary Topic
Electrical and Bioimpedance Tomography
Type
article
Field-Weighted Citation Impact
0.21
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Vector Network Analyzer (VNA) Measurements for Electrical Impedance Tomography

Alberto Battistel, Knut Möller, Ahmad Karime
1 citations
Current Directions in Biomedical Engineering
Electrical and Bioimpedance Tomography
0.21
article

Vector Network Analyzer (VNA) Measurements for Electrical Impedance Tomography

Alberto Battistel, Knut Möller, Ahmad Karime
article en
1 citations

Abstract

Abstract Electrical Impedance Tomography is a noninvasive imaging technique that employs electrical currents to reveal the internal conductivity distribution within the body. The study follows a new Radio Frequency (RF) approach, by using a Vector Network Analyzer to provide a multifrequency measurement between 10 kHz and 1 GHz. A plastic and a metallic object were positioned within a saline-filled phantom to test the EIT reconstructed images at different frequencies. The results show that based on the image reconstruction, the material’s conductivity can be distinguished at specific frequencies. However, beyond 10 MHz, the reconstructed images become less reliable until reaching 1 GHz, where the reconstructed image deteriorates significantly. While Electrical Impedance Tomography (EIT) has potential in new applications, its efficacy is limited by the ill-posed problem of the reconstruction. Further development and refinement of techniques, particularly in addressing issues that occur at higher frequencies, are required to realize EIT’s full potential in various fields.

Current Directions in Biomedical EngineeringVol. 10(4)
Furtwangen University (DE)
Openalex Percentile: Top 45%
Electrical and Bioimpedance Tomography
0.21
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.