Modeling Human Ventricular Cardiomyocyte Force-Frequency Relationship

Abstract We investigate the force-frequency relationship (FFR) representation of human ventricular cardiomyocyte models and point out shortcomings, motivated by discrepancies in whole-heart simulations at increased pacing rates. Utilizing the openCARP simulator, simulations across frequencies ranging from 1 Hz to 3 Hz were conducted. Experimental data on healthy human ventricular cardiomyocytes were collected and compared against simulated results. Results show deviations for all models, with Tomek et al. modeling time sensitive biomarkers the best. For example, the ratio of time to peak tension at 2 Hz and 1 Hz is around 85% for experiments, 82% for hybrid data, 95% for Tomek et al., 98% for O’Hara et al. and 138% for ten Tusscher et al. These discrepancies, highlight not only the need for careful selection of ionic models, but also the importance of refining ventricular cardiomyocyte models for advancing in-silico cardiac research.

Authors

Institutions

Publication Details

Journal
Current Directions in Biomedical Engineering
Published
2024-12-01
DOI
https://doi.org/10.1515/cdbme-2024-2051
Primary Topic
Elasticity and Material Modeling
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Modeling Human Ventricular Cardiomyocyte Force-Frequency Relationship

Axel Loewe, Jonathan Krauß, Jan-Erik Duhme
Current Directions in Biomedical Engineering
Elasticity and Material Modeling
article

Modeling Human Ventricular Cardiomyocyte Force-Frequency Relationship

Axel Loewe, Jonathan Krauß, Jan-Erik Duhme
article en

Abstract

Abstract We investigate the force-frequency relationship (FFR) representation of human ventricular cardiomyocyte models and point out shortcomings, motivated by discrepancies in whole-heart simulations at increased pacing rates. Utilizing the openCARP simulator, simulations across frequencies ranging from 1 Hz to 3 Hz were conducted. Experimental data on healthy human ventricular cardiomyocytes were collected and compared against simulated results. Results show deviations for all models, with Tomek et al. modeling time sensitive biomarkers the best. For example, the ratio of time to peak tension at 2 Hz and 1 Hz is around 85% for experiments, 82% for hybrid data, 95% for Tomek et al., 98% for O’Hara et al. and 138% for ten Tusscher et al. These discrepancies, highlight not only the need for careful selection of ionic models, but also the importance of refining ventricular cardiomyocyte models for advancing in-silico cardiac research.

Current Directions in Biomedical EngineeringVol. 10(4)
Karlsruhe Institute of Technology (DE)
Deutsche Forschungsgemeinschaft
Openalex Percentile: Top 78%
Elasticity and Material Modeling
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Modeling Human Ventricular Cardiomyocyte Force-Frequency Relationship — Axel Loewe, Jonathan Krauß, et al. · Current Directions in Biomedical Engineering (2024) | TGRS Research Map | TGRS