Advancements in Dexterity Measurements: the digital Nine Hole Peg Test

Abstract Digitalization in the healthcare sector is progressing rapidly. In the field of measuring instruments for manual dexterity, digitization has resulted in major limitations in terms of ease of use and usability. This study describes the development of a digital nine-hole peg test (dNHPT) for assessing hand dexterity that can be used just as easily and quickly as the original nine-hole peg test. The extensive validation of the dNHPT includes the investigation of validity, reliability, clinical utility and user-friendliness This paper presents the validation of clinical utility and usability of the dNHPT. The comparison of the original ninehole peg test (NHPT) und the dNHPT show similar clinical utility of the dNHPT and the NHPT (74% of all ratings of dNHPT are equal to or better than the NHPT) and good to excellent System Usability Scale Scores of 78 (CI95: 75;81) and 85 (CI95: 80;89). Several recommendations for further development of the dNHPT were identified. The newly developed dNHPT presented here supports the quality of data collection through automated time measurement and result presentation and shows good usability and clinical utility ratings.

Authors

Institutions

Publication Details

Journal
Current Directions in Biomedical Engineering
Published
2024-12-01
DOI
https://doi.org/10.1515/cdbme-2024-2125
Primary Topic
Advanced Measurement and Metrology Techniques
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Advancements in Dexterity Measurements: the digital Nine Hole Peg Test

Eveline Prochaska, Martin Sedlmayr
2 links
Current Directions in Biomedical Engineering
Advanced Measurement and Metrology Techniques
article

Advancements in Dexterity Measurements: the digital Nine Hole Peg Test

Eveline Prochaska, Martin Sedlmayr
article en

Abstract

Abstract Digitalization in the healthcare sector is progressing rapidly. In the field of measuring instruments for manual dexterity, digitization has resulted in major limitations in terms of ease of use and usability. This study describes the development of a digital nine-hole peg test (dNHPT) for assessing hand dexterity that can be used just as easily and quickly as the original nine-hole peg test. The extensive validation of the dNHPT includes the investigation of validity, reliability, clinical utility and user-friendliness This paper presents the validation of clinical utility and usability of the dNHPT. The comparison of the original ninehole peg test (NHPT) und the dNHPT show similar clinical utility of the dNHPT and the NHPT (74% of all ratings of dNHPT are equal to or better than the NHPT) and good to excellent System Usability Scale Scores of 78 (CI95: 75;81) and 85 (CI95: 80;89). Several recommendations for further development of the dNHPT were identified. The newly developed dNHPT presented here supports the quality of data collection through automated time measurement and result presentation and shows good usability and clinical utility ratings.

Current Directions in Biomedical EngineeringVol. 10(4)
Technische Universität Dresden (DE)
Openalex Percentile: Top 76%
Advanced Measurement and Metrology Techniques
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.