Early-detection of pre-eclampsia: Concept and design of a portable prototype

Abstract Pre-eclampsia is one of the most common causes of maternal and perinatal death worldwide. It is a hypertensive pregnancy disease with reduced perfusion of numerous organs. The main symptoms of the disease include elevated blood pressure, proteinuria and the associated subcutaneous fluid retention in the fingers, hands and face of the pregnant woman. In this paper a concept of a portable prototype for early-detection of preeclampsia is presented. The assembled sensor systems enable portable monitoring of the main symptoms to detect changes at an early stage. The sensor system for determining blood pressure is based on photoplethysmography. The sensor system for detecting subcutaneous fluid retention uses the absorption bands of the fluid when illuminated with near-infrared light. For the validation experiments, finger models made of silicone with different fluid retention levels were produced. The results show a correlation between the measured transmitted light intensity and the fluid retention. The results represent a possibility for the portable measurement of important vital parameters in connection with preeclampsia.

Authors

Institutions

Publication Details

Journal
Current Directions in Biomedical Engineering
Published
2024-12-01
DOI
https://doi.org/10.1515/cdbme-2024-2083
Primary Topic
Pregnancy and preeclampsia studies
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Early-detection of pre-eclampsia: Concept and design of a portable prototype

Julia Wagner, Peter Paul Pott, Swantje Janzen
Current Directions in Biomedical Engineering
Pregnancy and preeclampsia studies
article

Early-detection of pre-eclampsia: Concept and design of a portable prototype

Julia Wagner, Peter Paul Pott, Swantje Janzen
article en

Abstract

Abstract Pre-eclampsia is one of the most common causes of maternal and perinatal death worldwide. It is a hypertensive pregnancy disease with reduced perfusion of numerous organs. The main symptoms of the disease include elevated blood pressure, proteinuria and the associated subcutaneous fluid retention in the fingers, hands and face of the pregnant woman. In this paper a concept of a portable prototype for early-detection of preeclampsia is presented. The assembled sensor systems enable portable monitoring of the main symptoms to detect changes at an early stage. The sensor system for determining blood pressure is based on photoplethysmography. The sensor system for detecting subcutaneous fluid retention uses the absorption bands of the fluid when illuminated with near-infrared light. For the validation experiments, finger models made of silicone with different fluid retention levels were produced. The results show a correlation between the measured transmitted light intensity and the fluid retention. The results represent a possibility for the portable measurement of important vital parameters in connection with preeclampsia.

Current Directions in Biomedical EngineeringVol. 10(4)
University of Stuttgart (DE)
Openalex Percentile: Top 64%
Pregnancy and preeclampsia studies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Early-detection of pre-eclampsia: Concept and design of a portable prototype — Julia Wagner, Peter Paul Pott, et al. · Current Directions in Biomedical Engineering (2024) | TGRS Research Map | TGRS