Mathematical Modeling of the Operation of a Hydrophoric Installation

Abstract In this paper, the performance of a pumping system is considered in its operation with a hydrophore vessel connected in parallel. The filling and emptying processes of the hydrophore and their influence on the flow rate to the system and the pump outlet pressure are experimentally investigated. An automated measuring system is used for the measurements of the flow rate and the pressure. That has cyclically recorded the values at equal time intervals. The measurement cycles are synchronized in time and the maximum errors of the measured quantities are known. From the experimental data, empirical relationships are obtained for flow rate and pressure as a function of time, as well as the relationships between the two quantities. The time periods of each of the two processes and the average cycle length are also empirically determined. Confidence intervals of the flow rate are constructed for vessel filling and emptying, respectively, and measurement errors were accounted for. Codes have been created to determine the filling time of a hydrophore vessel and to calculate confidence intervals for this type of pumping systems, thanks to which all calculations have been automated. The described dependencies can be used in planning future experiments.

Authors

Institutions

Publication Details

Journal
Journal of Physics Conference Series
Published
2024-12-01
DOI
https://doi.org/10.1088/1742-6596/2910/1/012019
Citations
2
Primary Topic
Oil and Gas Production Techniques
Type
article
Field-Weighted Citation Impact
0.67
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Mathematical Modeling of the Operation of a Hydrophoric Installation

Ivaylo Nikolaev, Vesela Mihova, Elitsa Raeva
2 citations
Journal of Physics Conference Series
Oil and Gas Production Techniques
0.67
article

Mathematical Modeling of the Operation of a Hydrophoric Installation

Ivaylo Nikolaev, Vesela Mihova, Elitsa Raeva
article en
2 citations

Abstract

Abstract In this paper, the performance of a pumping system is considered in its operation with a hydrophore vessel connected in parallel. The filling and emptying processes of the hydrophore and their influence on the flow rate to the system and the pump outlet pressure are experimentally investigated. An automated measuring system is used for the measurements of the flow rate and the pressure. That has cyclically recorded the values at equal time intervals. The measurement cycles are synchronized in time and the maximum errors of the measured quantities are known. From the experimental data, empirical relationships are obtained for flow rate and pressure as a function of time, as well as the relationships between the two quantities. The time periods of each of the two processes and the average cycle length are also empirically determined. Confidence intervals of the flow rate are constructed for vessel filling and emptying, respectively, and measurement errors were accounted for. Codes have been created to determine the filling time of a hydrophore vessel and to calculate confidence intervals for this type of pumping systems, thanks to which all calculations have been automated. The described dependencies can be used in planning future experiments.

Journal of Physics Conference SeriesVol. 2910(1)
Angel Kanchev University of Ruse (BG)
Openalex Percentile: Top 29%
Oil and Gas Production Techniques
0.67
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.