The Halbach and alternating polarity linear magnets array are designed for microparticle separation, based on magnetophoresis

Abstract Particle separation using magnetophoresis requires an inhomogeneous magnetic field which affects the microparticle. The more changes in the magnetic field, the greater the magnetic force. The changes could exist in various ways. In this article, the change to produce a more intensive inhomogeneous magnetic field is generated by rotating the magnets to a specific degree. The analyses are done for three-state magnet arrays. For this purpose, a device is fabricated and the mentioned arrays are embedded in it. First, the results are simulated. The mathematical piecewise algorithm is used to validate the simulation. By examining the states in the fabricated device the experimental results are extracted. Overall, the results demonstrated that the Halbach and alternating polarity linear arrays (both 90, and 180 degrees) have better efficiency and throughput than the regular design array (without magnet rotating). The Halbach designs are illustrated with approximately the same results. However, in alternating polarity linear array, 180 degrees the particle capturing rate stood in a better place than the other design.

Authors

Institutions

Publication Details

Journal
Physica Scripta
Published
2024-12-18
DOI
https://doi.org/10.1088/1402-4896/ada119
Primary Topic
Microfluidic and Bio-sensing Technologies
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

The Halbach and alternating polarity linear magnets array are designed for microparticle separation, based on magnetophoresis

shahriar baghdadi, Mazdak Rad Malekshahi
Physica Scripta
Microfluidic and Bio-sensing Technologies
article

The Halbach and alternating polarity linear magnets array are designed for microparticle separation, based on magnetophoresis

shahriar baghdadi, Mazdak Rad Malekshahi
article en

Abstract

Abstract Particle separation using magnetophoresis requires an inhomogeneous magnetic field which affects the microparticle. The more changes in the magnetic field, the greater the magnetic force. The changes could exist in various ways. In this article, the change to produce a more intensive inhomogeneous magnetic field is generated by rotating the magnets to a specific degree. The analyses are done for three-state magnet arrays. For this purpose, a device is fabricated and the mentioned arrays are embedded in it. First, the results are simulated. The mathematical piecewise algorithm is used to validate the simulation. By examining the states in the fabricated device the experimental results are extracted. Overall, the results demonstrated that the Halbach and alternating polarity linear arrays (both 90, and 180 degrees) have better efficiency and throughput than the regular design array (without magnet rotating). The Halbach designs are illustrated with approximately the same results. However, in alternating polarity linear array, 180 degrees the particle capturing rate stood in a better place than the other design.

Physica ScriptaVol. 100(7)
Razi University (IR)
Affordable and clean energy
Openalex Percentile: Top 78%
Microfluidic and Bio-sensing Technologies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

The Halbach and alternating polarity linear magnets array are designed for microparticle separation, based on magnetophoresis — shahriar baghdadi, Mazdak Rad Malekshahi · Physica Scripta (2024) | TGRS Research Map | TGRS