Difficult airway foreign body removal
Foreign body (FB) aspiration in children is a common emergency. Traditionally, rigid bronchoscopy has been considered to be the mainstay for removal. However, in certain cases, flexible bronchoscopy can prove to be a better option and avoid thoracic surgery and unnecessary morbidity. Here, we describe the case of a child with accidental aspiration of a 4 cm long sewing needle, lodged in the lateral basal segment of the left lower lobe. Rigid bronchoscopy was unsuccessful as it could not access the distally placed needle. Instead, a flexible bronchoscopy performed through the endotracheal tube after sedating and paralysing the patient was effective and the needle could be grasped and removed using a wire basket. We describe our patient management protocol for paediatric airway FBs, which has been quite effective and prevents procedural delay. Expertise of the operator and a concerted team effort are the recipe for success.
Authors
- Krishna Mohan Gulla (ORCID: https://orcid.org/0000-0001-5031-5754)
- Golla Ramakrishna
- Ketan Kumar (ORCID: https://orcid.org/0000-0002-4038-7532)
- Rashmi Ranjan Das
Institutions
- All India Institute of Medical Sciences Bhubaneswar (IN)
Publication Details
- Journal
- BMJ Case Reports
- Published
- 2024-12-01
- DOI
- https://doi.org/10.1136/bcr-2024-262862
- Citations
- 3
- Primary Topic
- Foreign Body Medical Cases
- Type
- article
- Field-Weighted Citation Impact
- 1.21