Experimental analysis of parallel operation of two heat sources in a dual-source heat pump incorporating two compressors

Dual-source heat pumps have the potential to improve heating efficiency and / or the space required for heat sources. Parallel operation of two heat sources using two compressors can increase these benefits but poses technological challenges – specifically in the increased refrigerant cycle interconnection complexity, refrigerant and compressor oil management. These benefits and challenges have yet to be thoroughly investigated which is the primary objective of this research paper. An experimental analysis was conducted on a dual-source heat pump that utilized both an air heat source and a ground heat source. It included both individual and parallel operation modes of the heat sources. A prototype with a novel two-compressor interconnection was designed, manufactured, and tested in laboratory conditions. Analysis of the energetic benefit included efficiency evaluation at different ambient conditions and the corresponding loads on the ground source heat exchanger. Energetically, the single source operation showed comparable results in the coefficient of performance to conventional heat pumps despite the increased interconnection complexity. Parallel operation could efficiently cover heating loads at reduced load on the individual heat sources (at -7 °C, a reduction to 41 % on the ground-source and 58 % on the air-source heat exchanger). Technological challenges were highlighted in refrigerant and compressor oil shifts. While a control-based solution for the refrigerant shift was demonstrated, the oil shift requires further analysis of oil conditions in failing compressors.

Authors

Institutions

Publication Details

Journal
International Journal of Refrigeration
Published
2024-12-18
DOI
https://doi.org/10.1016/j.ijrefrig.2024.12.013
Citations
4
Primary Topic
Refrigeration and Air Conditioning Technologies
Type
article
Field-Weighted Citation Impact
0.85
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Experimental analysis of parallel operation of two heat sources in a dual-source heat pump incorporating two compressors

Fabian Ochs, Christoph Trinkl, Thorsten Summ, Tobias Reum et al.
4 citations
International Journal of Refrigeration
Refrigeration and Air Conditioning Technologies
0.85
article

Experimental analysis of parallel operation of two heat sources in a dual-source heat pump incorporating two compressors

Fabian Ochs, Christoph Trinkl, Thorsten Summ, Tobias Reum, Tobias Schrag, D. R. Schmitt
article en
4 citations

Abstract

Dual-source heat pumps have the potential to improve heating efficiency and / or the space required for heat sources. Parallel operation of two heat sources using two compressors can increase these benefits but poses technological challenges – specifically in the increased refrigerant cycle interconnection complexity, refrigerant and compressor oil management. These benefits and challenges have yet to be thoroughly investigated which is the primary objective of this research paper. An experimental analysis was conducted on a dual-source heat pump that utilized both an air heat source and a ground heat source. It included both individual and parallel operation modes of the heat sources. A prototype with a novel two-compressor interconnection was designed, manufactured, and tested in laboratory conditions. Analysis of the energetic benefit included efficiency evaluation at different ambient conditions and the corresponding loads on the ground source heat exchanger. Energetically, the single source operation showed comparable results in the coefficient of performance to conventional heat pumps despite the increased interconnection complexity. Parallel operation could efficiently cover heating loads at reduced load on the individual heat sources (at -7 °C, a reduction to 41 % on the ground-source and 58 % on the air-source heat exchanger). Technological challenges were highlighted in refrigerant and compressor oil shifts. While a control-based solution for the refrigerant shift was demonstrated, the oil shift requires further analysis of oil conditions in failing compressors.

International Journal of RefrigerationVol. 171
Universität Innsbruck (AT), Technische Hochschule Ingolstadt (DE)
Affordable and clean energy
Openalex Percentile: Top 29%
Refrigeration and Air Conditioning Technologies
0.85
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.