Integrating advanced Microfluidic lateral flow systems with a finger-prick blood collection cartridge to create an all-in-one platform for point-of-care diagnostics

Rapid, point-of-care tests are critical for early diagnosis of disease and detection of biological threats. Lateral flow immunoassays (LFIAs) are well-suited for point-of-care testing due to their ease of use and straightforward readout. However, limitations in sensitivity, quantification, and integration into sample-to-result systems indicate the need for further advancements. This paper introduces a novel all-in-one LFIA that integrates a test strip with optimized geometry within a newly designed finger-prick blood collection cartridge. This innovative system offers an efficient solution for the detection and quantification of hepatitis B antigens, combining precision and user-friendliness in a single device. To enhance assay performance, the conventional test strip's response to the target protein was significantly improved by incorporating a constricted test zone and upstream mixing elements. To meet self-testing requirements, the blood collection cartridge incorporates an innovative two-step rotation mechanism that simplifies sample collection, processing, and application onto the test strip. Numerical simulations of flow dynamics and antibody-antigen interactions using COMSOL guided the optimization of the test strip geometry, achieving a substantial improvement in the limit of detection from 1.78 ± 0.08 to 0.55 ± 0.04 ng/mL compared to the classic rectangular strip geometry. The optimized design also increased analytical sensitivity from 1.4 ± 0.1 to 2.8 ± 0.1 RU.mL/ng. The system demonstrated complete functionality, from sample collection to analyte quantification. This integrated, user-friendly platform provides an advanced, sample-to-result diagnostic solution for detecting disease markers from finger-prick blood samples. Its simplicity makes it suitable for point-of-care testing, including home use by non-professionals.

Authors

Institutions

Publication Details

Journal
Biosensors and Bioelectronics
Published
2024-12-19
DOI
https://doi.org/10.1016/j.bios.2024.117079
Citations
6
Primary Topic
Biosensors and Analytical Detection
Type
article
Field-Weighted Citation Impact
1.11

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Integrating advanced Microfluidic lateral flow systems with a finger-prick blood collection cartridge to create an all-in-one platform for point-of-care diagnostics

Alireza Norouzi Azad, Sergey N. Krylov, Razieh Salahandish, Fatemeh Haghayegh et al.
6 citations
Biosensors and Bioelectronics
Biosensors and Analytical Detection
1.11
article

Integrating advanced Microfluidic lateral flow systems with a finger-prick blood collection cartridge to create an all-in-one platform for point-of-care diagnostics

Alireza Norouzi Azad, Sergey N. Krylov, Razieh Salahandish, Fatemeh Haghayegh, Ryan Orszulik, Elnaz Haghani, Hamidreza Akbari Ghavamabadi, Sunil Aggarwal, Ashissh Raichura
article en
6 citations

Abstract

Rapid, point-of-care tests are critical for early diagnosis of disease and detection of biological threats. Lateral flow immunoassays (LFIAs) are well-suited for point-of-care testing due to their ease of use and straightforward readout. However, limitations in sensitivity, quantification, and integration into sample-to-result systems indicate the need for further advancements. This paper introduces a novel all-in-one LFIA that integrates a test strip with optimized geometry within a newly designed finger-prick blood collection cartridge. This innovative system offers an efficient solution for the detection and quantification of hepatitis B antigens, combining precision and user-friendliness in a single device. To enhance assay performance, the conventional test strip's response to the target protein was significantly improved by incorporating a constricted test zone and upstream mixing elements. To meet self-testing requirements, the blood collection cartridge incorporates an innovative two-step rotation mechanism that simplifies sample collection, processing, and application onto the test strip. Numerical simulations of flow dynamics and antibody-antigen interactions using COMSOL guided the optimization of the test strip geometry, achieving a substantial improvement in the limit of detection from 1.78 ± 0.08 to 0.55 ± 0.04 ng/mL compared to the classic rectangular strip geometry. The optimized design also increased analytical sensitivity from 1.4 ± 0.1 to 2.8 ± 0.1 RU.mL/ng. The system demonstrated complete functionality, from sample collection to analyte quantification. This integrated, user-friendly platform provides an advanced, sample-to-result diagnostic solution for detecting disease markers from finger-prick blood samples. Its simplicity makes it suitable for point-of-care testing, including home use by non-professionals.

Biosensors and BioelectronicsVol. 271
York University (CA), Membrane Reactor Technologies (Canada) (CA)
York University, Mitacs, Natural Sciences and Engineering Research Council of Canada
Openalex Percentile: Top 24%
Biosensors and Analytical Detection
1.11
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.