A non-contact optical uniaxial tension-unloading strain measurement

A tension-compression test is necessary to investigate the impact of the kinematic hardening model’s parameters on the springback following sheet metal stamping processes. However, conventional cyclic testing using extensometers faces challenges due to buckling issues. Therefore, the implementing of Digital Image Correlation (DIC), a non-contact optical measurement system, becomes crucial. The present investigation involved the simultaneous use of an extensometer and an AutoGrid optical strain measurement system to perform a uniaxial tension-unloading test on aluminum alloy AA6082-T6. Both measurement systems were evaluated based on the comparison of the time-displacement, time-force, true stress-true strain, and reduction of Young’s modulus due to deformation. The results show that the force, change in displacement, and stress-strain values obtained by the two measurement techniques are comparable and close. It demonstrates that the DIC method has high accuracy and moderate agreement with conventional extensometer.

Authors

Institutions

Publication Details

Journal
Multidiszciplináris Tudományok
Published
2024-11-29
DOI
https://doi.org/10.35925/j.multi.2024.2.16
Primary Topic
Optical measurement and interference techniques
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

A non-contact optical uniaxial tension-unloading strain measurement

Zsolt Lukács, Jemal Ebrahim Dessie, Péter Kovács, Rahmato Abdulhakim Shukurea
Multidiszciplináris Tudományok
Optical measurement and interference techniques
article

A non-contact optical uniaxial tension-unloading strain measurement

Zsolt Lukács, Jemal Ebrahim Dessie, Péter Kovács, Rahmato Abdulhakim Shukurea
article en

Abstract

A tension-compression test is necessary to investigate the impact of the kinematic hardening model’s parameters on the springback following sheet metal stamping processes. However, conventional cyclic testing using extensometers faces challenges due to buckling issues. Therefore, the implementing of Digital Image Correlation (DIC), a non-contact optical measurement system, becomes crucial. The present investigation involved the simultaneous use of an extensometer and an AutoGrid optical strain measurement system to perform a uniaxial tension-unloading test on aluminum alloy AA6082-T6. Both measurement systems were evaluated based on the comparison of the time-displacement, time-force, true stress-true strain, and reduction of Young’s modulus due to deformation. The results show that the force, change in displacement, and stress-strain values obtained by the two measurement techniques are comparable and close. It demonstrates that the DIC method has high accuracy and moderate agreement with conventional extensometer.

Multidiszciplináris TudományokVol. 14(2)
University of Miskolc (HU)
Openalex Percentile: Top 77%
Optical measurement and interference techniques
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.