Non-suppressed ion chromatography-tandem electrospray mass spectrometry using a short column for simultaneous analysis of dichloroacetic acid, trichloroacetic acid, and bromate: aqueous ammonia as the eluent additive

Dichloroacetic acid (DCAA), trichloroacetic acid (TCAA), and bromate (BrO<sub>3</sub><sup>-</sup>) are disinfection byproducts (DBPs) formed during drinking water treatment and pose health risks. Rapid and reliable detection of these DBPs is essential for ensuring water safety. Non-suppressed ion chromatography (IC)-electrospray ionization mass spectrometry (IC-ESI-MS/MS) offers a promising approach for simultaneous analysis of organic haloacetic acids (HAAs) and inorganic oxyhalides, but previous methods using toxic methylamine can pose health risks. Herein, a new rapid non-suppressed IC-ESI-MS/MS method using a short AG18 guard column (13 μm, 2 mm × 50 mm) with aqueous ammonia as the alkaline modifier was developed for the simultaneous quantification of DCAA, TCAA, and BrO<sub>3</sub><sup>-</sup>. This method allows direct sample injection without pretreatment and achieves sub-μg L<sup>-1</sup> detection limits within 5 minutes. Aqueous ammonia (0.4 M) and acetonitrile were used as mobile phases in a gradient elution mode, providing good linearity (<i>R</i><sup>2</sup> >0.995), low limits of quantification (0.48-1.13 μg L<sup>-1</sup>), and high recoveries (76.3-107.3%). Intra-day (<i>n</i> = 9) and inter-day (3 days, <i>n</i> = 9) precision were validated with relative standard deviations of 5.8-8.9% and 6.4-7.7%, respectively. The method also demonstrated limited matrix interference from common water parameters such as Cl<sup>-</sup>, SO<sub>4</sub><sup>2-</sup>, HCO<sub>3</sub><sup>-</sup>/CO<sub>3</sub><sup>2-</sup>, and natural organic matter (NOM), making it suitable for real water analysis. The applicability of this method was confirmed by monitoring DBP formation during the chlorination of NOM, showing that two-step chlorine dosing strategies reduce DBP formation compared to single-stage dosing. This newly established method provides a robust and efficient tool for DBP monitoring in drinking water treatment processes.

Authors

Institutions

Publication Details

Journal
Analytical Methods
Published
2024-12-18
DOI
https://doi.org/10.1039/d4ay02007c
Citations
1
Primary Topic
Analytical Chemistry and Chromatography
Type
article
Field-Weighted Citation Impact
0.24
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Non-suppressed ion chromatography-tandem electrospray mass spectrometry using a short column for simultaneous analysis of dichloroacetic acid, trichloroacetic acid, and bromate: aqueous ammonia as the eluent additive

Yanting Zuo, Mingguo Peng, Erdeng Du, Qiang Cheng et al.
1 citations
Analytical Methods
Analytical Chemistry and Chromatography
0.24
article

Non-suppressed ion chromatography-tandem electrospray mass spectrometry using a short column for simultaneous analysis of dichloroacetic acid, trichloroacetic acid, and bromate: aqueous ammonia as the eluent additive

Yanting Zuo, Mingguo Peng, Erdeng Du, Qiang Cheng, Shi Cheng, Aimin Li, Jiali Chen, Huaicheng Zhang, Liangtao Pu
article en
1 citations

Abstract

Dichloroacetic acid (DCAA), trichloroacetic acid (TCAA), and bromate (BrO<sub>3</sub><sup>-</sup>) are disinfection byproducts (DBPs) formed during drinking water treatment and pose health risks. Rapid and reliable detection of these DBPs is essential for ensuring water safety. Non-suppressed ion chromatography (IC)-electrospray ionization mass spectrometry (IC-ESI-MS/MS) offers a promising approach for simultaneous analysis of organic haloacetic acids (HAAs) and inorganic oxyhalides, but previous methods using toxic methylamine can pose health risks. Herein, a new rapid non-suppressed IC-ESI-MS/MS method using a short AG18 guard column (13 μm, 2 mm × 50 mm) with aqueous ammonia as the alkaline modifier was developed for the simultaneous quantification of DCAA, TCAA, and BrO<sub>3</sub><sup>-</sup>. This method allows direct sample injection without pretreatment and achieves sub-μg L<sup>-1</sup> detection limits within 5 minutes. Aqueous ammonia (0.4 M) and acetonitrile were used as mobile phases in a gradient elution mode, providing good linearity (<i>R</i><sup>2</sup> >0.995), low limits of quantification (0.48-1.13 μg L<sup>-1</sup>), and high recoveries (76.3-107.3%). Intra-day (<i>n</i> = 9) and inter-day (3 days, <i>n</i> = 9) precision were validated with relative standard deviations of 5.8-8.9% and 6.4-7.7%, respectively. The method also demonstrated limited matrix interference from common water parameters such as Cl<sup>-</sup>, SO<sub>4</sub><sup>2-</sup>, HCO<sub>3</sub><sup>-</sup>/CO<sub>3</sub><sup>2-</sup>, and natural organic matter (NOM), making it suitable for real water analysis. The applicability of this method was confirmed by monitoring DBP formation during the chlorination of NOM, showing that two-step chlorine dosing strategies reduce DBP formation compared to single-stage dosing. This newly established method provides a robust and efficient tool for DBP monitoring in drinking water treatment processes.

Analytical MethodsVol. 17(4)
State Key Laboratory of Pollution Control and Resource Reuse (CN), Jiangsu University of Technology (CN), Changzhou University (CN), Nanjing Polytechnic Institute (CN), Nanjing University (CN)
Clean water and sanitation
Openalex Percentile: Top 47%
Analytical Chemistry and Chromatography
0.24
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.