Transcatheter aortic valve implantation (TAVI) is recommended for treatment of high-risk aortic stenosis patients. While measuring mean transaortic valve gradient (MG) is crucial in evaluating procedural success, echocardiographic measurements often overestimate direct invasive measurements. This study aimed to examine the discordance between echocardiographic and invasive MGs in TAVI patients and assess their prognostic value on long-term outcomes. This prospective registry included consecutive TAVI patients at a tertiary university hospital. Transthoracic or transoesophageal echocardiography was performed pre-TAVI, at discharge, 1 month, 1, and 5 years with invasive MG measurements obtained peri-procedurally. The primary endpoints were 5-year all-cause mortality and major adverse cardiac events. Among 1353 patients from 2011 to 2023, non-invasive MGs exceeded invasive MGs pre- and post-implantation (43 [36, 52] mmHg vs. 40 [30, 50] mmHg, p < 0.001; 9 [6, 12] mmHg vs. 4 [2, 7] mmHg, p < 0.001) Pre-procedural MGs correlated better than post-procedural MGs (r = 0.70, p < 0.001 vs. r = 0.23, p < 0.001), particularly in self-expandable valves and smaller sinus of Valsalva diameter (SOVd) (r = 0.33, p < 0.001; r = 0.46, p < 0.001 vs R = 0.06, p = 0.701). Non-invasive MG remained stable from discharge (9 [6, 12] mmHg) to 5 years (9 [7, 12] mmHg). While structural valve deterioration and patient-prosthesis mismatch showed no impact, extreme invasive MGs (< 3 or > 6 mmHg) predicted worse outcomes (mortality hazard: 1.25 [1.06, 1.88] and 0.85 [0.8, 0.95], respectively), unlike non-invasive measurements. In conclusion, invasive as compared with non-invasive MGs correlated better before than after valve implantation, whereas invasive MGs were always lower than non-invasive MGs. Lower invasive MGs after TAVI appeared to be associated with favourable long-term outcomes.

Authors

Institutions

Publication Details

Journal
Cardiovascular Intervention and Therapeutics
Published
2024-12-19
DOI
https://doi.org/10.1007/s12928-024-01074-6
Citations
7
Primary Topic
Cardiac Valve Diseases and Treatments
Type
article
Field-Weighted Citation Impact
2.81

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Comparison of invasive and non-invasive gradients before and after TAVI and their implications on clinical outcomes

Gregor Leibundgut, Thorald Stolte, Felix Mahfoud, Jakob Johannes Reichl et al.
7 citations
Cardiovascular Intervention and Therapeutics
Cardiac Valve Diseases and Treatments
2.81
article

Comparison of invasive and non-invasive gradients before and after TAVI and their implications on clinical outcomes

Gregor Leibundgut, Thorald Stolte, Felix Mahfoud, Jakob Johannes Reichl, Thomas Nestelberger, Max Wagener, Jasper Boeddinghaus, Anna Pfenniger, Christoph Ado Kaiser
article en
7 citations

Abstract

Transcatheter aortic valve implantation (TAVI) is recommended for treatment of high-risk aortic stenosis patients. While measuring mean transaortic valve gradient (MG) is crucial in evaluating procedural success, echocardiographic measurements often overestimate direct invasive measurements. This study aimed to examine the discordance between echocardiographic and invasive MGs in TAVI patients and assess their prognostic value on long-term outcomes. This prospective registry included consecutive TAVI patients at a tertiary university hospital. Transthoracic or transoesophageal echocardiography was performed pre-TAVI, at discharge, 1 month, 1, and 5 years with invasive MG measurements obtained peri-procedurally. The primary endpoints were 5-year all-cause mortality and major adverse cardiac events. Among 1353 patients from 2011 to 2023, non-invasive MGs exceeded invasive MGs pre- and post-implantation (43 [36, 52] mmHg vs. 40 [30, 50] mmHg, p < 0.001; 9 [6, 12] mmHg vs. 4 [2, 7] mmHg, p < 0.001) Pre-procedural MGs correlated better than post-procedural MGs (r = 0.70, p < 0.001 vs. r = 0.23, p < 0.001), particularly in self-expandable valves and smaller sinus of Valsalva diameter (SOVd) (r = 0.33, p < 0.001; r = 0.46, p < 0.001 vs R = 0.06, p = 0.701). Non-invasive MG remained stable from discharge (9 [6, 12] mmHg) to 5 years (9 [7, 12] mmHg). While structural valve deterioration and patient-prosthesis mismatch showed no impact, extreme invasive MGs (< 3 or > 6 mmHg) predicted worse outcomes (mortality hazard: 1.25 [1.06, 1.88] and 0.85 [0.8, 0.95], respectively), unlike non-invasive measurements. In conclusion, invasive as compared with non-invasive MGs correlated better before than after valve implantation, whereas invasive MGs were always lower than non-invasive MGs. Lower invasive MGs after TAVI appeared to be associated with favourable long-term outcomes.

Cardiovascular Intervention and TherapeuticsVol. 40(2)
University of Basel (CH), University Hospital of Basel (CH), Hospital Base (CL), École Polytechnique Fédérale de Lausanne (CH)
Universität Basel, Schweizerischer Nationalfonds zur Förderung der Wissenschaftlichen Forschung
Good health and well-being
Openalex Percentile: Top 8%
Cardiac Valve Diseases and Treatments
2.81
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.