Multiple optical path length reflections enhancement based on balloon-type photoacoustic cell for trace gas sensing

A novel balloon-type photoacoustic cell (BTPAC) is proposed to facilitate the detection limitations of acetylene (C<sub>2</sub>H<sub>2</sub>) gas achieving ppb level. Here, an ellipsoidal photoacoustic cavity is employed as the platform for gas-light interaction. By strategically directing the excitation source towards the focal point of the ellipsoidal cavity, ensuring its trajectory traverses the focal point upon each reflection from the interior walls. This path increases the gas absorption path length and improves the efficiency of the laser-gas interaction process. Experimental results show that the quality factor of the BTPAC is 224.24 under normal temperature and pressure conditions. Notably, the system maintains a high signal-to-noise ratio even at a C<sub>2</sub>H<sub>2</sub> concentration of 0.1 ppm. Moreover, the minimum detection limit (MDL) and normalized noise equivalent absorption can be calculated to be 3.86 ppb, 6.94·10<sup>-10</sup> cm<sup>-1</sup>·W·Hz<sup>-1/2</sup>, respectively. Finally, the MDL of the sensor reaches to 0.71 ppb when the integration time reaches 100 s.

Authors

Institutions

Publication Details

Journal
Photoacoustics
Published
2024-12-18
DOI
https://doi.org/10.1016/j.pacs.2024.100681
Citations
8
Primary Topic
Spectroscopy and Laser Applications
Type
article
Field-Weighted Citation Impact
1.93

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Multiple optical path length reflections enhancement based on balloon-type photoacoustic cell for trace gas sensing

Zhongke Zhao, Ping Lü, Sixiang Ran, Wenjun Ni et al.
8 citations
Photoacoustics
Spectroscopy and Laser Applications
1.93
article

Multiple optical path length reflections enhancement based on balloon-type photoacoustic cell for trace gas sensing

Zhongke Zhao, Ping Lü, Sixiang Ran, Wenjun Ni, Ruiming Wu, Boxin He, Perry Ping Shum, Chunyong Yang
article en
8 citations

Abstract

A novel balloon-type photoacoustic cell (BTPAC) is proposed to facilitate the detection limitations of acetylene (C<sub>2</sub>H<sub>2</sub>) gas achieving ppb level. Here, an ellipsoidal photoacoustic cavity is employed as the platform for gas-light interaction. By strategically directing the excitation source towards the focal point of the ellipsoidal cavity, ensuring its trajectory traverses the focal point upon each reflection from the interior walls. This path increases the gas absorption path length and improves the efficiency of the laser-gas interaction process. Experimental results show that the quality factor of the BTPAC is 224.24 under normal temperature and pressure conditions. Notably, the system maintains a high signal-to-noise ratio even at a C<sub>2</sub>H<sub>2</sub> concentration of 0.1 ppm. Moreover, the minimum detection limit (MDL) and normalized noise equivalent absorption can be calculated to be 3.86 ppb, 6.94·10<sup>-10</sup> cm<sup>-1</sup>·W·Hz<sup>-1/2</sup>, respectively. Finally, the MDL of the sensor reaches to 0.71 ppb when the integration time reaches 100 s.

PhotoacousticsVol. 41
Minzu University of China (CN), Southern University of Science and Technology (CN), Wuhan National Laboratory for Optoelectronics (CN), Huazhong University of Science and Technology (CN)
National Natural Science Foundation of China, Natural Science Foundation of Hubei Province
Affordable and clean energy
Openalex Percentile: Top 14%
Spectroscopy and Laser Applications
1.93
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.