Low-Voltage Biological Electric Shock Fault Diagnosis Based on the Attention Mechanism Fusion Parallel Convolutional Neural Network/Bidirectional Long Short-Term Memory Model

Electric shock protection is critical for ensuring power safety in low-voltage grids, and robust fault diagnosis methods provide an essential foundation for the accurate operation of such protection devices. However, current low-voltage electric shock protection devices often suffer from limitations in operational precision and in their ability to effectively recognize electric shock types. To address these challenges, this paper proposes a fault diagnosis method for low-voltage electric shocks based on an attention-enhanced parallel CNN-BiLSTM model. The method first utilizes CNN to extract local spatial features of the electric shock signal and BiLSTM to capture temporal features. An attention mechanism is then introduced to fuse the local spatial and temporal features with weighted emphasis. Finally, a fully connected layer maps the fused features to the output layer, generating diagnostic results. Visualization through T-SNE analysis validates the improvement in model performance due to the attention mechanism. Comparative experiments show that the proposed model outperforms single models and other combined models in terms of accuracy, precision, recall, F1 score, and convergence speed. The results demonstrate that the proposed model achieves a fault diagnosis accuracy of 99.55%.

Authors

Institutions

Publication Details

Journal
Mathematics
Published
2024-12-18
DOI
https://doi.org/10.3390/math12243984
Citations
2
Primary Topic
Machine Learning in Bioinformatics
Type
article
Field-Weighted Citation Impact
0.47

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Low-Voltage Biological Electric Shock Fault Diagnosis Based on the Attention Mechanism Fusion Parallel Convolutional Neural Network/Bidirectional Long Short-Term Memory Model

Zhirong Qiu, Yuliang Luo, Meijin Lin, Zibin Dai et al.
2 citations
Mathematics
Machine Learning in Bioinformatics
0.47
article

Low-Voltage Biological Electric Shock Fault Diagnosis Based on the Attention Mechanism Fusion Parallel Convolutional Neural Network/Bidirectional Long Short-Term Memory Model

Zhirong Qiu, Yuliang Luo, Meijin Lin, Zibin Dai, Senjie Chen
article en
2 citations

Abstract

Electric shock protection is critical for ensuring power safety in low-voltage grids, and robust fault diagnosis methods provide an essential foundation for the accurate operation of such protection devices. However, current low-voltage electric shock protection devices often suffer from limitations in operational precision and in their ability to effectively recognize electric shock types. To address these challenges, this paper proposes a fault diagnosis method for low-voltage electric shocks based on an attention-enhanced parallel CNN-BiLSTM model. The method first utilizes CNN to extract local spatial features of the electric shock signal and BiLSTM to capture temporal features. An attention mechanism is then introduced to fuse the local spatial and temporal features with weighted emphasis. Finally, a fully connected layer maps the fused features to the output layer, generating diagnostic results. Visualization through T-SNE analysis validates the improvement in model performance due to the attention mechanism. Comparative experiments show that the proposed model outperforms single models and other combined models in terms of accuracy, precision, recall, F1 score, and convergence speed. The results demonstrate that the proposed model achieves a fault diagnosis accuracy of 99.55%.

MathematicsVol. 12(24)
Foshan University (CN)
China Southern Power Grid
Affordable and clean energy
Openalex Percentile: Top 33%
Machine Learning in Bioinformatics
0.47
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Low-Voltage Biological Electric Shock Fault Diagnosis Based on the Attention Mechanism Fusion Parallel Convolutional Neural Network/Bidirectional Long Short-Term Memory Model — Zhirong Qiu, Yuliang Luo, et al. · Mathematics (2024) | TGRS Research Map | TGRS