Power Flow Control and Mode-Switching Method Considering Single-Pole Trip for Bipolar MTDC System

Due to the advantage of the system operation reliability and flexibility, the bipolar multi-terminal high voltage dc (MTDC) transmission has attracted worldwide attention for the integration of offshore windfarms. However, majority of existing operation methods and dc power flow algorithms are designed to control the monopolar MTDC system. It is difficult to implement the conventional control method for the monopolar system into the bipolar system due to the difference in the characteristics of dc power flow control scheme between the two configurations. Therefore, this paper proposes an operation method of the bipolar MTDC system composed of the dc power flow control scheme and mode-switching method. As a simulation result, the proposed method can realize the power sharing between each VSC and reduce the impact of the active power fluctuation on the AC grid connected to the system even when the single-pole trip occurs in the bipolar MTDC system.

Authors

Institutions

Publication Details

Published
2024-10-21
DOI
https://doi.org/10.1109/icue63019.2024.10795532
Primary Topic
HVDC Systems and Fault Protection
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Power Flow Control and Mode-Switching Method Considering Single-Pole Trip for Bipolar MTDC System

Naoto Kodama, Ayaka Nakamura, Mikimasa Iwata, Yasunobu Yokomizu
HVDC Systems and Fault Protection
article

Power Flow Control and Mode-Switching Method Considering Single-Pole Trip for Bipolar MTDC System

Naoto Kodama, Ayaka Nakamura, Mikimasa Iwata, Yasunobu Yokomizu
article en

Abstract

Due to the advantage of the system operation reliability and flexibility, the bipolar multi-terminal high voltage dc (MTDC) transmission has attracted worldwide attention for the integration of offshore windfarms. However, majority of existing operation methods and dc power flow algorithms are designed to control the monopolar MTDC system. It is difficult to implement the conventional control method for the monopolar system into the bipolar system due to the difference in the characteristics of dc power flow control scheme between the two configurations. Therefore, this paper proposes an operation method of the bipolar MTDC system composed of the dc power flow control scheme and mode-switching method. As a simulation result, the proposed method can realize the power sharing between each VSC and reduce the impact of the active power fluctuation on the AC grid connected to the system even when the single-pole trip occurs in the bipolar MTDC system.

Nagoya University (JP)
Affordable and clean energy
Openalex Percentile: Top 79%
HVDC Systems and Fault Protection
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.