Advanced Design of Capacitive Micromachined Ultrasonic Transducers with Ultra-Low Quality Factor

in this work, we present the design and fabrication of a capacitive micromachined ultrasonic transducer optimized for medical imaging applications. Leveraging the squeeze film damping effect, we achieved a quality factor of approximately 2, which addresses the common challenge of high Q leading to blurred images in high-frequency sensors. Our design minimizes array side lobes and interference, resulting in a sharper array main lobe and reduced image artifacts. By utilizing the PolyMUMPS standard fabrication process, we ensure consistent sensor performance, contributing to more reliable and precise imaging.

Authors

Institutions

Publication Details

Published
2024-09-22
DOI
https://doi.org/10.1109/uffc-js60046.2024.10793970
Citations
1
Primary Topic
Engineering Applied Research
Type
article
Field-Weighted Citation Impact
0.26
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Advanced Design of Capacitive Micromachined Ultrasonic Transducers with Ultra-Low Quality Factor

Mahta Moghaddam, Frédéric Nabki, Abid Ali, Ilgar Jafarsadeghi Pournaki et al.
1 citations
Engineering Applied Research
0.26
article

Advanced Design of Capacitive Micromachined Ultrasonic Transducers with Ultra-Low Quality Factor

Mahta Moghaddam, Frédéric Nabki, Abid Ali, Ilgar Jafarsadeghi Pournaki, Amirhossein Moshrefi
article en
1 citations

Abstract

in this work, we present the design and fabrication of a capacitive micromachined ultrasonic transducer optimized for medical imaging applications. Leveraging the squeeze film damping effect, we achieved a quality factor of approximately 2, which addresses the common challenge of high Q leading to blurred images in high-frequency sensors. Our design minimizes array side lobes and interference, resulting in a sharper array main lobe and reduced image artifacts. By utilizing the PolyMUMPS standard fabrication process, we ensure consistent sensor performance, contributing to more reliable and precise imaging.

École de Technologie Supérieure (CA)
Affordable and clean energy
Openalex Percentile: Top 42%
Engineering Applied Research
0.26
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.