Super-Resolution Ultrasound Imaging using Erythrocytes on an Axillary Human Lymph Node

A recent contrast-free super-resolution ultrasound imaging technique using erythrocytes (SURE) has been introduced. SURE can create quantitative images of the microvasculature without contrast agents in just a few seconds. Previously, SURE was applied in-vivo in laparotomized rats to generate images of the renal microvasculature. Now, it is advancing into human studies, with a focus on lymph nodes in this paper. The potential of SURE extends to diagnosing and monitoring diseases affecting the microvasculature of human lymph nodes. This paper hypothesizes that SURE can transcutaneously reveal microvascular density and flow images of human lymph nodes without contrast agents in just 2 seconds of acquisition. An axillary human lymph node is used in this study, and the SURE density image from the Verasonics research scanner is compared with the color Doppler image from a commercial GE LOGIQ E9 scanner. In this study, the SURE tracking pipeline could depict and estimate the velocity image and the velocity profile of vessels down to 67 µm in diameter with 16.4 mm/s.

Authors

Institutions

Publication Details

Published
2024-09-22
DOI
https://doi.org/10.1109/uffc-js60046.2024.10793752
Citations
2
Primary Topic
Ultrasound Imaging and Elastography
Type
article
Field-Weighted Citation Impact
0.81

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Super-Resolution Ultrasound Imaging using Erythrocytes on an Axillary Human Lymph Node

Nathalie Sarup Panduro, Michael Bachmann Nielsen, Jørgen Arendt Jensen, Charlotte Mehlin Sørensen et al.
2 citations
Ultrasound Imaging and Elastography
0.81
article

Super-Resolution Ultrasound Imaging using Erythrocytes on an Axillary Human Lymph Node

Nathalie Sarup Panduro, Michael Bachmann Nielsen, Jørgen Arendt Jensen, Charlotte Mehlin Sørensen, Mostafa Amin Naji, Ali Salari, Seyed Mohammad Mahdi Tabatabaei Majd
article en
2 citations

Abstract

A recent contrast-free super-resolution ultrasound imaging technique using erythrocytes (SURE) has been introduced. SURE can create quantitative images of the microvasculature without contrast agents in just a few seconds. Previously, SURE was applied in-vivo in laparotomized rats to generate images of the renal microvasculature. Now, it is advancing into human studies, with a focus on lymph nodes in this paper. The potential of SURE extends to diagnosing and monitoring diseases affecting the microvasculature of human lymph nodes. This paper hypothesizes that SURE can transcutaneously reveal microvascular density and flow images of human lymph nodes without contrast agents in just 2 seconds of acquisition. An axillary human lymph node is used in this study, and the SURE density image from the Verasonics research scanner is compared with the color Doppler image from a commercial GE LOGIQ E9 scanner. In this study, the SURE tracking pipeline could depict and estimate the velocity image and the velocity profile of vessels down to 67 µm in diameter with 16.4 mm/s.

University of Copenhagen (DK), Rigshospitalet (DK), Technical University of Denmark (DK)
European Research Council
Openalex Percentile: Top 24%
Ultrasound Imaging and Elastography
0.81
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Super-Resolution Ultrasound Imaging using Erythrocytes on an Axillary Human Lymph Node — Nathalie Sarup Panduro, Michael Bachmann Nielsen, et al. · (2024) | TGRS Research Map | TGRS