Vector Measurement of Nonlinear Responses Generated by SAW/BAW RF Devices Using Lock-in Amplifiers

This paper describes a development of vector (amplitude and phase) measurement system for detecting nonlinear responses generated by SAW/BAW RF devices. The system employs universal lock-in amplifiers instead of unique equipment such as the Cross-Domain Analyzer (XDA). As demonstrations, the second- and the third-order harmonic responses generated by a one-port SAW resonator whose resonant and anti-resonant frequencies are 833.8 and 862.8 [MHz], respectively, are measured. The measured amplitude and phase by the proposed method coincide with those measured by the XDA with reasonable accuracy. This result demonstrates that the proposed method can measure feeble nonlinear responses from the SAW/BAW RF devices as vector data, with at least comparable SNR with those measured by the XDA. The proposed measurement system provides practical tools to acquire the complex amplitude of nonlinear responses from the SAW/BAW RF devices.

Authors

Institutions

Publication Details

Published
2024-09-22
DOI
https://doi.org/10.1109/uffc-js60046.2024.10793743
Citations
3
Primary Topic
Acoustic Wave Resonator Technologies
Type
article
Field-Weighted Citation Impact
0.55
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Vector Measurement of Nonlinear Responses Generated by SAW/BAW RF Devices Using Lock-in Amplifiers

T. Doi, Tatsuya Omori
3 citations
Acoustic Wave Resonator Technologies
0.55
article

Vector Measurement of Nonlinear Responses Generated by SAW/BAW RF Devices Using Lock-in Amplifiers

T. Doi, Tatsuya Omori
article en
3 citations

Abstract

This paper describes a development of vector (amplitude and phase) measurement system for detecting nonlinear responses generated by SAW/BAW RF devices. The system employs universal lock-in amplifiers instead of unique equipment such as the Cross-Domain Analyzer (XDA). As demonstrations, the second- and the third-order harmonic responses generated by a one-port SAW resonator whose resonant and anti-resonant frequencies are 833.8 and 862.8 [MHz], respectively, are measured. The measured amplitude and phase by the proposed method coincide with those measured by the XDA with reasonable accuracy. This result demonstrates that the proposed method can measure feeble nonlinear responses from the SAW/BAW RF devices as vector data, with at least comparable SNR with those measured by the XDA. The proposed measurement system provides practical tools to acquire the complex amplitude of nonlinear responses from the SAW/BAW RF devices.

Chiba University (JP)
Affordable and clean energy
Openalex Percentile: Top 36%
Acoustic Wave Resonator Technologies
0.55
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Vector Measurement of Nonlinear Responses Generated by SAW/BAW RF Devices Using Lock-in Amplifiers — T. Doi, Tatsuya Omori · (2024) | TGRS Research Map | TGRS