Ultra-Sensitive Cascaded Integrated Photonic Ultrasound Transducers (IPUTs)

Echography is an important medical diagnostic technique. Historically, the key improvement driver was the hypothesis that higher image quality leads to better diagnoses and increased patient health. Here, a major parameter is the signal to noise ratio (SNR). Diffraction and attenuation reduce pressure levels during propagation. Thus, an SNR increase yields detection at larger depths benefitting traditionally difficult to image patients (eg large/obese patients). Peak pressures are limited by safety standards (mechanical/thermal index). Thus, to increase SNR more sensitive transducers are required. The state of the art Noise Equivalent Pressure (NEP) for piezotransducers / cMUTs / pMUTs is ~0.5 Pa at 1 MHz [1],[2],[3]. A recent innovation is the Integrated Photonic Ultrasound Transducer (IPUT), which combines a membrane and a photonic waveguide to measure ultrasound waves. Literature [5] reported such a device producing a 0.38 Pa NEP at 0.47 MHz and 21% -6 dB bandwidth with a 169x smaller spatial footprint compared to 0.5 x 0.5 wavelength<sup xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">2</sup>. Here, we cascade IPUTs into array elements and transform IPUT sensitivity per area into high absolute sensitivity. Several transducer elements were created by cascading up to 16 IPUTs. After designing these devices, their performance was predicted, and subsequently they were fabricated via VTT’s 3 µm thick silicon-on-insulator (SOI) waveguide platform. IPUT performance was measured in a water tank using a custom calibrated source transducer. The transfer functions and noise of each signal chain component was measured and analyzed. The results showed for a 5 cascaded IPUT element a measured NEP of 4 mPa at 0.54 MHz with a 13% -6 dB bandwidth. This improves on the state-of-the-art by a factor of 90-116x.

Authors

Institutions

Publication Details

Published
2024-09-22
DOI
https://doi.org/10.1109/uffc-js60046.2024.10793785
Primary Topic
Photoacoustic and Ultrasonic Imaging
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Ultra-Sensitive Cascaded Integrated Photonic Ultrasound Transducers (IPUTs)

Sami Ylinen, Yisbel E. Marin, Daniele Piras, Martin D. Verweij et al.
2 links
Photoacoustic and Ultrasonic Imaging
article

Ultra-Sensitive Cascaded Integrated Photonic Ultrasound Transducers (IPUTs)

Sami Ylinen, Yisbel E. Marin, Daniele Piras, Martin D. Verweij, Mikko Harjanne, M. P. Oderwald, Sabiju Valiya Valappil, Srivathsa Bhat, Päivi Heimala, Maurits S. van der Heiden, Robert Altmann, P.L.M.J. van Neer, Thomas Jansen, P.J. Harmsma, B.A.J. Quesson, Anne Maaike Gerritsma
article en

Abstract

Echography is an important medical diagnostic technique. Historically, the key improvement driver was the hypothesis that higher image quality leads to better diagnoses and increased patient health. Here, a major parameter is the signal to noise ratio (SNR). Diffraction and attenuation reduce pressure levels during propagation. Thus, an SNR increase yields detection at larger depths benefitting traditionally difficult to image patients (eg large/obese patients). Peak pressures are limited by safety standards (mechanical/thermal index). Thus, to increase SNR more sensitive transducers are required. The state of the art Noise Equivalent Pressure (NEP) for piezotransducers / cMUTs / pMUTs is ~0.5 Pa at 1 MHz [1],[2],[3]. A recent innovation is the Integrated Photonic Ultrasound Transducer (IPUT), which combines a membrane and a photonic waveguide to measure ultrasound waves. Literature [5] reported such a device producing a 0.38 Pa NEP at 0.47 MHz and 21% -6 dB bandwidth with a 169x smaller spatial footprint compared to 0.5 x 0.5 wavelength<sup xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">2</sup>. Here, we cascade IPUTs into array elements and transform IPUT sensitivity per area into high absolute sensitivity. Several transducer elements were created by cascading up to 16 IPUTs. After designing these devices, their performance was predicted, and subsequently they were fabricated via VTT’s 3 µm thick silicon-on-insulator (SOI) waveguide platform. IPUT performance was measured in a water tank using a custom calibrated source transducer. The transfer functions and noise of each signal chain component was measured and analyzed. The results showed for a 5 cascaded IPUT element a measured NEP of 4 mPa at 0.54 MHz with a 13% -6 dB bandwidth. This improves on the state-of-the-art by a factor of 90-116x.

Netherlands Organisation for Applied Scientific Research (NL), VTT Technical Research Centre of Finland (FI), Delft University of Technology (NL)
Affordable and clean energy
Openalex Percentile: Top 78%
Photoacoustic and Ultrasonic Imaging
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.