Size-Selected Microbubbles for Superharmonic Contrast Imaging

The nonlinear behavior of microbubbles (MBs) is dependent on both the excitation pressure and the MB properties, which rely on the composition of the gas core and shell, as well as the size. Polydisperse MBs have a broad size distribution and only a subpopulation of them may be contributing to the higher order harmonics that are used for superharmonic imaging. High MB concentrations have been used for superharmonic imaging to produce nonlinear responses from the polydisperse MB solution for good image contrast. In this work, we investigate in vitro the contrast signal intensity and longivity with in-house polydisperse MBs and size-selected MBs of ~1.5, 2.2, and 4.3 µm in diameter, comparing to commonly used MicroMarker MB solutions. We found the in-house 2.2 µm MBs showed comparable mean contrast intensities and signal decay to MicroMarker. We evaluated these two populations in vivo on mouse kidneys over an approximately 18-minute imaging duration, and assessed quantitatively the contrast intensities and longevity of superharmonic signals. We found MicroMarker showed greater superharmonic contrast over the entire acquisition in vivo, with a half-life almost twice to that of the in-house 2.2 µm MBs.

Authors

Institutions

Publication Details

Published
2024-09-22
DOI
https://doi.org/10.1109/uffc-js60046.2024.10793460
Primary Topic
Photoacoustic and Ultrasonic Imaging
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Size-Selected Microbubbles for Superharmonic Contrast Imaging

F. Stuart Foster, Christine Démoré, David E. Goertz, Jing Yang et al.
Photoacoustic and Ultrasonic Imaging
article

Size-Selected Microbubbles for Superharmonic Contrast Imaging

F. Stuart Foster, Christine Démoré, David E. Goertz, Jing Yang, Amin Jafari Sojahrood
article en

Abstract

The nonlinear behavior of microbubbles (MBs) is dependent on both the excitation pressure and the MB properties, which rely on the composition of the gas core and shell, as well as the size. Polydisperse MBs have a broad size distribution and only a subpopulation of them may be contributing to the higher order harmonics that are used for superharmonic imaging. High MB concentrations have been used for superharmonic imaging to produce nonlinear responses from the polydisperse MB solution for good image contrast. In this work, we investigate in vitro the contrast signal intensity and longivity with in-house polydisperse MBs and size-selected MBs of ~1.5, 2.2, and 4.3 µm in diameter, comparing to commonly used MicroMarker MB solutions. We found the in-house 2.2 µm MBs showed comparable mean contrast intensities and signal decay to MicroMarker. We evaluated these two populations in vivo on mouse kidneys over an approximately 18-minute imaging duration, and assessed quantitatively the contrast intensities and longevity of superharmonic signals. We found MicroMarker showed greater superharmonic contrast over the entire acquisition in vivo, with a half-life almost twice to that of the in-house 2.2 µm MBs.

Sunnybrook Health Science Centre (CA), University of Toronto (CA), Sunnybrook Hospital (CA), Sunnybrook Research Institute
HORIZON EUROPE Health
Openalex Percentile: Top 78%
Photoacoustic and Ultrasonic Imaging
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.