Comparative Analysis of Technical Solutions for Secondary Systems in Substations with a “Breaker-and-a-Half” Scheme

Based on their purpose and functions within the power system, substations in the Republic of Bulgaria are classified into system substations, distribution substations, and transformer stations. System substations connect different parts of the power system as well as two different power systems. Because system substations are supplied by transmission power lines and handle large power flows, they have increased reliability requirements. To meet these requirements, design solutions are implemented, which include electrical scheme configurations for switchyards with multiple connections, such as the “breaker-and-a-half” scheme. The technical solutions for measurement systems, operational power supplies, control, protection, signaling, and communication can be collectively summarized as secondary system. This paper will specifically examine these technical solutions, taking into account the advantages and disadvantages of the “breaker-and-a-half” scheme.

Authors

Institutions

Publication Details

Published
2024-09-19
DOI
https://doi.org/10.1109/bulef63204.2024.10794895
Primary Topic
Industrial Engineering and Technologies
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Comparative Analysis of Technical Solutions for Secondary Systems in Substations with a “Breaker-and-a-Half” Scheme

Ivan Tenchev, Daniel Dobrilov, Valeri Uzunov, Lyudmil Kirilov et al.
Industrial Engineering and Technologies
article

Comparative Analysis of Technical Solutions for Secondary Systems in Substations with a “Breaker-and-a-Half” Scheme

Ivan Tenchev, Daniel Dobrilov, Valeri Uzunov, Lyudmil Kirilov, Adelin Antonov
article en

Abstract

Based on their purpose and functions within the power system, substations in the Republic of Bulgaria are classified into system substations, distribution substations, and transformer stations. System substations connect different parts of the power system as well as two different power systems. Because system substations are supplied by transmission power lines and handle large power flows, they have increased reliability requirements. To meet these requirements, design solutions are implemented, which include electrical scheme configurations for switchyards with multiple connections, such as the “breaker-and-a-half” scheme. The technical solutions for measurement systems, operational power supplies, control, protection, signaling, and communication can be collectively summarized as secondary system. This paper will specifically examine these technical solutions, taking into account the advantages and disadvantages of the “breaker-and-a-half” scheme.

Technical University of Sofia (BG)
Openalex Percentile: Top 76%
Industrial Engineering and Technologies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Comparative Analysis of Technical Solutions for Secondary Systems in Substations with a “Breaker-and-a-Half” Scheme — Ivan Tenchev, Daniel Dobrilov, et al. · (2024) | TGRS Research Map | TGRS