Biocompatible Hermetic Encapsulation of PMUTs for Usage in Implantable Medical Devices

This study reports on the encapsulation of piezoelectric micromachined ultrasonic transducer (PMUT) devices by hermetic Parylene F-VT4 (PVT4) and multilayer stacks of PVT4 combined with atomic layer deposition films. These encapsulations are evaluated for their potential to enable implantable PMUT devices for biomedical applications, providing necessary protection for both the device and the patient while preserving device performance. The mechanical and acoustic properties of coated and uncoated single PMUTs and 64x64 PMUT arrays were characterized in water. Results indicate that the resonance frequencies of both the single elements and the arrays change non-monotonically with increasing PVT4 thickness due to alterations in the equivalent mechanical properties of the composite membrane. While single PMUTs exhibited a monotonic decrease in displacement, encapsulation significantly improved the array's pressure output, attributed to changes in acoustic wavelength and inter-element coupling. This enhancement underscores the effectiveness of encapsulation in optimizing overall performance.

Authors

Institutions

Publication Details

Published
2024-09-22
DOI
https://doi.org/10.1109/uffc-js60046.2024.10793944
Citations
1
Primary Topic
biodegradable polymer synthesis and properties
Type
article
Field-Weighted Citation Impact
0.17
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Biocompatible Hermetic Encapsulation of PMUTs for Usage in Implantable Medical Devices

Véronique Rochus, Xavier Rottenberg, Rik Verplancke, Pieter Gijsenbergh et al.
1 citations
biodegradable polymer synthesis and properties
0.17
article

Biocompatible Hermetic Encapsulation of PMUTs for Usage in Implantable Medical Devices

Véronique Rochus, Xavier Rottenberg, Rik Verplancke, Pieter Gijsenbergh, Maarten Cauwe, Maaike Op de Beeck, Esmaeil Afshari, Samer Houri
article en
1 citations

Abstract

This study reports on the encapsulation of piezoelectric micromachined ultrasonic transducer (PMUT) devices by hermetic Parylene F-VT4 (PVT4) and multilayer stacks of PVT4 combined with atomic layer deposition films. These encapsulations are evaluated for their potential to enable implantable PMUT devices for biomedical applications, providing necessary protection for both the device and the patient while preserving device performance. The mechanical and acoustic properties of coated and uncoated single PMUTs and 64x64 PMUT arrays were characterized in water. Results indicate that the resonance frequencies of both the single elements and the arrays change non-monotonically with increasing PVT4 thickness due to alterations in the equivalent mechanical properties of the composite membrane. While single PMUTs exhibited a monotonic decrease in displacement, encapsulation significantly improved the array's pressure output, attributed to changes in acoustic wavelength and inter-element coupling. This enhancement underscores the effectiveness of encapsulation in optimizing overall performance.

IMEC (BE)
Openalex Percentile: Top 49%
biodegradable polymer synthesis and properties
0.17
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.