Significant Improvement in SNR of PMUTs by Using Transimpedance Amplifier: A Promising Architecture Towards Canonical Ultrasound Medical Imaging

This paper represents a different approach to increasing the signal-to-noise ratio (SNR) of piezoelectric micromachined ultrasound transducers (pMUTs) during reception, instead of the typical low-noise voltage amplifiers used for classical bulk PZT ultrasound transducers. Since a pMUT is modeled as a current source in its equivalent electrical model, a transimpedance amplifier (TIA) with very low input impedance has been utilized to capture all the current produced by the pMUTs of one transducer channel and convert it into voltage. We demonstrated an improvement of 27 dB in the dynamic range of a pMUT array, easily achieving a total dynamic range of 70 dB. These results are significant as they make medical imaging with a pMUT array less dependent on the quality and performance of the piezoelectric thin film.

Authors

Institutions

Publication Details

Published
2024-09-22
DOI
https://doi.org/10.1109/uffc-js60046.2024.10793922
Citations
1
Primary Topic
Ultrasound and Hyperthermia Applications
Type
article
Field-Weighted Citation Impact
0.18
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Significant Improvement in SNR of PMUTs by Using Transimpedance Amplifier: A Promising Architecture Towards Canonical Ultrasound Medical Imaging

Michael D. Kraft, J. Collado, Sina Sadeghpour, Rui Amendoeira et al.
1 citations
Ultrasound and Hyperthermia Applications
0.18
article

Significant Improvement in SNR of PMUTs by Using Transimpedance Amplifier: A Promising Architecture Towards Canonical Ultrasound Medical Imaging

Michael D. Kraft, J. Collado, Sina Sadeghpour, Rui Amendoeira, Behnam Madadnia
article en
1 citations

Abstract

This paper represents a different approach to increasing the signal-to-noise ratio (SNR) of piezoelectric micromachined ultrasound transducers (pMUTs) during reception, instead of the typical low-noise voltage amplifiers used for classical bulk PZT ultrasound transducers. Since a pMUT is modeled as a current source in its equivalent electrical model, a transimpedance amplifier (TIA) with very low input impedance has been utilized to capture all the current produced by the pMUTs of one transducer channel and convert it into voltage. We demonstrated an improvement of 27 dB in the dynamic range of a pMUT array, easily achieving a total dynamic range of 70 dB. These results are significant as they make medical imaging with a pMUT array less dependent on the quality and performance of the piezoelectric thin film.

KU Leuven (BE)
Openalex Percentile: Top 49%
Ultrasound and Hyperthermia Applications
0.18
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.