Image Guidance of a Phased Array Transducer for Neuromodulation with a Small Focal Volume

Transcranial focused ultrasound (tFUS) can modulate the brain using neuronavigation systems that guide where tFUS is delivered. However, neuronavigation systems can have up to 3-mm of targeting error. Previous tFUS systems have circumvented these targeting errors by using transducers with large focal volumes. However, these large focal volumes also deliver large amounts of pressure to off-target brain regions. Here, we describe a method that integrates a phased array into a neuronavigation system with a broadened focus that ensures sonication at the selected target while minimizing off-target effects. We show the broadened focus delivers significantly less energy off-target and has a focal volume of 189.07mm<sup xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">3</sup> which is more than 8 times smaller than the focus created by other common single element transducers.

Authors

Institutions

Publication Details

Published
2024-09-22
DOI
https://doi.org/10.1109/uffc-js60046.2024.10793628
Primary Topic
Engineering Technology and Methodologies
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Image Guidance of a Phased Array Transducer for Neuromodulation with a Small Focal Volume

Jiro Kusunose, Charles F. Caskey, Thilo Womelsdorf, Adam Neumann et al.
Engineering Technology and Methodologies
article

Image Guidance of a Phased Array Transducer for Neuromodulation with a Small Focal Volume

Jiro Kusunose, Charles F. Caskey, Thilo Womelsdorf, Adam Neumann, M. Anthony Phipps, Robert Louie Treuting, Malachy Newman, Allison Q Dockum
article en

Abstract

Transcranial focused ultrasound (tFUS) can modulate the brain using neuronavigation systems that guide where tFUS is delivered. However, neuronavigation systems can have up to 3-mm of targeting error. Previous tFUS systems have circumvented these targeting errors by using transducers with large focal volumes. However, these large focal volumes also deliver large amounts of pressure to off-target brain regions. Here, we describe a method that integrates a phased array into a neuronavigation system with a broadened focus that ensures sonication at the selected target while minimizing off-target effects. We show the broadened focus delivers significantly less energy off-target and has a focal volume of 189.07mm<sup xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">3</sup> which is more than 8 times smaller than the focus created by other common single element transducers.

Vanderbilt University (US), Vanderbilt University Medical Center (US)
Affordable and clean energy
Openalex Percentile: Top 66%
Engineering Technology and Methodologies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.