A High Fill-Factor High Density Large PMUT Phased Array

A PZT-based high fill-factor high density large PMUT array is designed and fabricated with 64 array elements and integrating a total of 15360 PMUT cells (cavity size 85μm). The impedance test result indicates that the device exhibits a resonant frequency of 4.2 MHz in vacuum. In the hydrophone measurements, the average sound pressure of one single channel of PMUT array is 9.08 kPa in water at the distance of 6mm with a input of 10Vpp. A broad -3dB-bandwidth(5.2MHz) is observed which is 176% of the center frequency. After implementing necessary signal filtering and amplification, high-contrast imaging of the sheep-spine in the phantom is obtained. The results affirm the array's potential in ultrasound imaging, particularly highlighting its significant promise for future applications in human body imaging.

Authors

Institutions

Publication Details

Published
2024-09-22
DOI
https://doi.org/10.1109/uffc-js60046.2024.10793791
Citations
2
Primary Topic
Microwave Engineering and Waveguides
Type
article
Field-Weighted Citation Impact
0.42
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

A High Fill-Factor High Density Large PMUT Phased Array

Zunliang Wang, Xiaoduo Zhang, Xiaoxiang Gao, Yinjie Ma et al.
2 citations
Microwave Engineering and Waveguides
0.42
article

A High Fill-Factor High Density Large PMUT Phased Array

Zunliang Wang, Xiaoduo Zhang, Xiaoxiang Gao, Yinjie Ma, Jingqi Chen, Hanzhang Liu, Hui Li, Zhengyu Li, Feng Yin, Chuan Chen
article en
2 citations

Abstract

A PZT-based high fill-factor high density large PMUT array is designed and fabricated with 64 array elements and integrating a total of 15360 PMUT cells (cavity size 85μm). The impedance test result indicates that the device exhibits a resonant frequency of 4.2 MHz in vacuum. In the hydrophone measurements, the average sound pressure of one single channel of PMUT array is 9.08 kPa in water at the distance of 6mm with a input of 10Vpp. A broad -3dB-bandwidth(5.2MHz) is observed which is 176% of the center frequency. After implementing necessary signal filtering and amplification, high-contrast imaging of the sheep-spine in the phantom is obtained. The results affirm the array's potential in ultrasound imaging, particularly highlighting its significant promise for future applications in human body imaging.

State Key Laboratory of Digital Medical Engineering (CN), Southeast University (CN)
Affordable and clean energy
Openalex Percentile: Top 36%
Microwave Engineering and Waveguides
0.42
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.