Short-Range Small-Form-Factor 2D Source Localization Using pMUT-Based Delay-Multiply-and-Sum Imaging Towards Catheter Coordination

This work presents, for the first time, in-immersion source localization using an imaging scheme with a lead zirconate titanate (PZT) piezoelectric micromachined ultrasonic transducer (pMUT) array. Initially, the received data is calibrated and bandpass filtered to removed undesired signal contributions. For the image reconstruction, Delay-Multiply-and-Sum with multiplier-of-2-signals (DMAS2) processing is employed with the source position determined from the coordinates of the pixel of maximum intensity within the reconstructed image. Experimental data are collected using PZT pMUTs immersed in a FC-70 fluid for the validation of the method with the results denoting that the proposed method accurately localizes the source with a 91.6% mean range accuracy and a 3.6° angle absolute error across an impressive -40°/+40° Field-of-View. The impressive results for the first time, benchmark pMUT-based imaging for catheter coordination (i.e., external source tracking of an internal invasive catheter).

Authors

Institutions

Publication Details

Published
2024-09-22
DOI
https://doi.org/10.1109/uffc-js60046.2024.10793880
Primary Topic
Photoacoustic and Ultrasonic Imaging
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Short-Range Small-Form-Factor 2D Source Localization Using pMUT-Based Delay-Multiply-and-Sum Imaging Towards Catheter Coordination

Ravi Shankar, Alberto Leotti, Peter H. K. Chang, Yul Koh et al.
Photoacoustic and Ultrasonic Imaging
article

Short-Range Small-Form-Factor 2D Source Localization Using pMUT-Based Delay-Multiply-and-Sum Imaging Towards Catheter Coordination

Ravi Shankar, Alberto Leotti, Peter H. K. Chang, Yul Koh, David Sze Wai Choong, Duan Jian Goh, Mantalena Sarafianou, Goutham Koppisetti, Srinivas Merugu, Domenico Giusti, Qing Xin Zhang
article en

Abstract

This work presents, for the first time, in-immersion source localization using an imaging scheme with a lead zirconate titanate (PZT) piezoelectric micromachined ultrasonic transducer (pMUT) array. Initially, the received data is calibrated and bandpass filtered to removed undesired signal contributions. For the image reconstruction, Delay-Multiply-and-Sum with multiplier-of-2-signals (DMAS2) processing is employed with the source position determined from the coordinates of the pixel of maximum intensity within the reconstructed image. Experimental data are collected using PZT pMUTs immersed in a FC-70 fluid for the validation of the method with the results denoting that the proposed method accurately localizes the source with a 91.6% mean range accuracy and a 3.6° angle absolute error across an impressive -40°/+40° Field-of-View. The impressive results for the first time, benchmark pMUT-based imaging for catheter coordination (i.e., external source tracking of an internal invasive catheter).

Agency for Science, Technology and Research (SG), Institute of Microelectronics (SG), STMicroelectronics (Singapore) (SG), STMicroelectronics (Italy) (IT)
Openalex Percentile: Top 78%
Photoacoustic and Ultrasonic Imaging
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Short-Range Small-Form-Factor 2D Source Localization Using pMUT-Based Delay-Multiply-and-Sum Imaging Towards Catheter Coordination — Ravi Shankar, Alberto Leotti, et al. · (2024) | TGRS Research Map | TGRS