Thermal Design Calculation of Boilers Type PK-38-4M in Operation with Gas Turbine
To integrate the available equipment of the 177 MW double power units into the combined cycle with the gas turbine, it is necessary to verify whether the PK-38- 4M boilers will be able to achieve the current steam parameters. Simulation modeling allows us to investigate the performance of these boilers in operation with gas turbines. In this article, the performance of PK-38-4M boilers when operating with different gas turbines in the Thermoflex simulation environment is analyzed.
Authors
- Borislav Ignatov
- Totyo Totev
- Vasil Radenkov (ORCID: https://orcid.org/0009-0001-4222-1827)
Institutions
- Trakia University (BG)
Publication Details
- Published
- 2024-09-19
- DOI
- https://doi.org/10.1109/bulef63204.2024.10794971
- Primary Topic
- Advanced Power Generation Technologies
- Type
- article
- Field-Weighted Citation Impact
- 0.00