Simplified Ultrasonic Imaging Sensor Based on Distributed Electrode Activation Control

The present research is focused on the development of an ultrasound imaging system based on a single-element configuration with distributed electrodes. The aforementioned process was conducted by regulating the activation of the constituent elements for the purposes of transmitting and receiving, with the assistance of a switching circuitry. The physical movement required by the single element with coding mask scenario in the previous study was addressed by the proposed scenario. In this work, we propose a single transducer with distributed electrodes by investigating the number of elements for transmitting and receiving. To enhance image resolution, we applied a weighted frequency subbands compound to the aforementioned model. The results demonstrate that the weighted frequency subbands compound was an effective approach to improve image resolution, as evidenced by the experimental data using the wire target and human carotid artery.

Authors

Institutions

Publication Details

Published
2024-09-22
DOI
https://doi.org/10.1109/uffc-js60046.2024.10794169
Citations
1
Primary Topic
Sensor Technology and Measurement Systems
Type
article
Field-Weighted Citation Impact
0.35

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Simplified Ultrasonic Imaging Sensor Based on Distributed Electrode Activation Control

Ming Yang, Mohd. Syaryadhi, Norio Tagawa, Eiko Nakazawa
1 citations
Sensor Technology and Measurement Systems
0.35
article

Simplified Ultrasonic Imaging Sensor Based on Distributed Electrode Activation Control

Ming Yang, Mohd. Syaryadhi, Norio Tagawa, Eiko Nakazawa
article en
1 citations

Abstract

The present research is focused on the development of an ultrasound imaging system based on a single-element configuration with distributed electrodes. The aforementioned process was conducted by regulating the activation of the constituent elements for the purposes of transmitting and receiving, with the assistance of a switching circuitry. The physical movement required by the single element with coding mask scenario in the previous study was addressed by the proposed scenario. In this work, we propose a single transducer with distributed electrodes by investigating the number of elements for transmitting and receiving. To enhance image resolution, we applied a weighted frequency subbands compound to the aforementioned model. The results demonstrate that the weighted frequency subbands compound was an effective approach to improve image resolution, as evidenced by the experimental data using the wire target and human carotid artery.

Tokyo Metropolitan University (JP)
Tokyo Metropolitan University
Affordable and clean energy
Openalex Percentile: Top 35%
Sensor Technology and Measurement Systems
0.35
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Simplified Ultrasonic Imaging Sensor Based on Distributed Electrode Activation Control — Ming Yang, Mohd. Syaryadhi, et al. · (2024) | TGRS Research Map | TGRS