Continuous Bernoulli Distribution for More Realistic Ultrasound Reconstruction with NeRF

Three-dimensional visualization offers a significantly improved depiction of the underlying anatomical structure; however conventional ultrasound typically provides two-dimensional B-mode images of anatomical regions in real time. Recent breakthroughs in computer graphics have leveraged the ability of Neural Radiance Fields (NeRF) to reconstruct three-dimensional scenes implicitly. This is achieved by formulating the three-dimensional scenes as continuous signals using multi-layer perception (MLP). The reconstructed images can be viewed from novel perspectives using a differentiable rendering method. However, current methods cannot recover complex ultrasound anatomical structures and can introduce artifacts, which impact the reconstruction quality. We propose a probabilistic and differentiable approach to estimate backscattered data to provide a more realistic three-dimensional ultrasound reconstruction with NeRF. Our proposed method achieves an improved peak signal-to-noise ratio (PSNR) score of 27.73±0.98 dB compared to the baseline method with 26.31±1.91 dB, along with an improved structural similarity index measure (SSIM) value of 0.47±0.21 to 0.54±0.19 for NeRF.

Authors

Institutions

Publication Details

Published
2024-09-22
DOI
https://doi.org/10.1109/uffc-js60046.2024.10793769
Citations
1
Primary Topic
Seismic Imaging and Inversion Techniques
Type
article
Field-Weighted Citation Impact
0.53

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Continuous Bernoulli Distribution for More Realistic Ultrasound Reconstruction with NeRF

Tomy Varghese, Yimeng Dou
1 citations
Seismic Imaging and Inversion Techniques
0.53
article

Continuous Bernoulli Distribution for More Realistic Ultrasound Reconstruction with NeRF

Tomy Varghese, Yimeng Dou
article en
1 citations

Abstract

Three-dimensional visualization offers a significantly improved depiction of the underlying anatomical structure; however conventional ultrasound typically provides two-dimensional B-mode images of anatomical regions in real time. Recent breakthroughs in computer graphics have leveraged the ability of Neural Radiance Fields (NeRF) to reconstruct three-dimensional scenes implicitly. This is achieved by formulating the three-dimensional scenes as continuous signals using multi-layer perception (MLP). The reconstructed images can be viewed from novel perspectives using a differentiable rendering method. However, current methods cannot recover complex ultrasound anatomical structures and can introduce artifacts, which impact the reconstruction quality. We propose a probabilistic and differentiable approach to estimate backscattered data to provide a more realistic three-dimensional ultrasound reconstruction with NeRF. Our proposed method achieves an improved peak signal-to-noise ratio (PSNR) score of 27.73±0.98 dB compared to the baseline method with 26.31±1.91 dB, along with an improved structural similarity index measure (SSIM) value of 0.47±0.21 to 0.54±0.19 for NeRF.

University of Wisconsin–Madison (US)
National Institutes of Health
Openalex Percentile: Top 31%
Seismic Imaging and Inversion Techniques
0.53
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.