Macrovascular contributions to resting-state fMRI signals: A comparison between EPI and bSSFP at 9.4 Tesla
The draining-vein bias of T2<sup>*</sup>-weighted sequences, like gradient echo echo-planar imaging (GRE-EPI), can limit the spatial specificity of functional MRI (fMRI). The underlying extravascular signal changes increase with field strength (B<sub>0</sub>) and the perpendicularity of draining veins to the main axis of B<sub>0</sub>, and are, therefore, particularly problematic at ultra-high field (UHF). In contrast, simulations showed that T2-weighted sequences are less affected by the draining-vein bias, depending on the amount of rephasing of extravascular signal. As large pial veins on the cortical surface follow the cortical folding tightly, their orientation can be approximated by the cortical orientation to <mml:math xmlns:mml="http://www.w3.org/1998/Math/MathML"> <mml:mrow> <mml:mover> <mml:mrow><mml:msub><mml:mi>B</mml:mi> <mml:mn>0</mml:mn></mml:msub> </mml:mrow> <mml:mo>→</mml:mo></mml:mover> </mml:mrow> </mml:math> . In our work, we compare the influence of the cortical orientation to <mml:math xmlns:mml="http://www.w3.org/1998/Math/MathML"> <mml:mrow> <mml:mover> <mml:mrow><mml:msub><mml:mi>B</mml:mi> <mml:mn>0</mml:mn></mml:msub> </mml:mrow> <mml:mo>→</mml:mo></mml:mover> </mml:mrow> </mml:math> on the resting-state fMRI signal of three sequences aiming to understand their macrovascular contribution. While 2D GRE-EPI and 3D GRE-EPI (both T2<sup>*</sup>-weighted) showed a high dependence on the cortical orientation to <mml:math xmlns:mml="http://www.w3.org/1998/Math/MathML"> <mml:mrow> <mml:mover> <mml:mrow><mml:msub><mml:mi>B</mml:mi> <mml:mn>0</mml:mn></mml:msub> </mml:mrow> <mml:mo>→</mml:mo></mml:mover> </mml:mrow> </mml:math> , especially on the cortical surface, this was not the case for 3D balanced steady-state free precession (bSSFP) (T2/T1-weighted). Here, a slight increase of orientation dependence was shown in depths closest to white matter (WM). And while orientation dependence decreased with increased distance to the veins for both EPI sequences, no change in orientation dependence was observed in bSSFP. This indicates the low macrovascular contribution to the bSSFP signal, making it a promising sequence for layer fMRI at UHF.
Authors
- Ruediger Stirnberg
- Philipp Ehses (ORCID: https://orcid.org/0000-0002-5839-6525)
- J Bause (ORCID: https://orcid.org/0000-0003-3915-3541)
- Dario Bosch (ORCID: https://orcid.org/0000-0002-6537-6370)
- Sebastian Mueller (ORCID: https://orcid.org/0000-0003-2699-9214)
- Dana Ramadan (ORCID: https://orcid.org/0009-0004-5539-2651)
- Klaus Scheffler
Institutions
- German Center for Neurodegenerative Diseases (DE)
- Max Planck Institute for Biological Cybernetics (DE)
- University of Tübingen (DE)
Publication Details
- Journal
- Imaging Neuroscience
- Published
- 2024-12-18
- DOI
- https://doi.org/10.1162/imag_a_00435
- Citations
- 4
- Primary Topic
- Advanced MRI Techniques and Applications
- Type
- article
- Field-Weighted Citation Impact
- 1.62