Adaptive eigen subspace projection for suppressing HIFU interference

High-intensity focused ultrasound (HIFU) is widely used in non-invasive thermal therapy. During HIFU therapy, ultrasound imaging offers the advantage of non-invasive and real-time monitoring. However, the artifacts caused by the HIFU system can obscure the information about the biological tissue in the ultrasound image. In this study, we introduce a one-dimensional adaptive eigen subspace projection (AESP) method to distinguish HIFU interference from the contaminated data. Ex vivo experiments on a clinical HIFU platform to validate the feasibility of the proposed algorithm. The results indicate that the AESP technique effectively suppresses artifacts produced by HIFU. In contrast to images processed with notch filtering, the AESP processed images show no residual artifacts. These findings demonstrate that AESP has significant potential to improve the efficacy and safety of HIFU treatment.

Authors

Institutions

Publication Details

Published
2024-09-22
DOI
https://doi.org/10.1109/uffc-js60046.2024.10794116
Citations
1
Primary Topic
Radar Systems and Signal Processing
Type
article
Field-Weighted Citation Impact
1.30
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Adaptive eigen subspace projection for suppressing HIFU interference

Kun Yang, Xiaowei Zhou, Qiang Li
1 citations
Radar Systems and Signal Processing
1.30
article

Adaptive eigen subspace projection for suppressing HIFU interference

Kun Yang, Xiaowei Zhou, Qiang Li
article en
1 citations

Abstract

High-intensity focused ultrasound (HIFU) is widely used in non-invasive thermal therapy. During HIFU therapy, ultrasound imaging offers the advantage of non-invasive and real-time monitoring. However, the artifacts caused by the HIFU system can obscure the information about the biological tissue in the ultrasound image. In this study, we introduce a one-dimensional adaptive eigen subspace projection (AESP) method to distinguish HIFU interference from the contaminated data. Ex vivo experiments on a clinical HIFU platform to validate the feasibility of the proposed algorithm. The results indicate that the AESP technique effectively suppresses artifacts produced by HIFU. In contrast to images processed with notch filtering, the AESP processed images show no residual artifacts. These findings demonstrate that AESP has significant potential to improve the efficacy and safety of HIFU treatment.

Tianjin University (CN), Chongqing Medical University (CN)
Climate action
Openalex Percentile: Top 11%
Radar Systems and Signal Processing
1.30
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.