A Flexible Body-Conformable Ultrasound Transducer Array for Neuromodulation Applications

Ultrasound neuromodulation offers a noninvasive treatment for neuropathic diseases, providing exceptional spatial resolution and deeper penetration than electrical neural stimulation. However, existing ultrasound transducers face challenges in precise targeting, adjustable treatment areas, and patient comfort. This study presents a flexible body-conformable ultrasound transducer array (FBUTA) designed for precise and comfortable neuromodulation. Utilizing advanced flexible materials, the FBUTA comprises 6 × 6 elements with a center frequency of 0.67 MHz, demonstrating excellent uniformity and stability across all elements, as well as superior mechanical performance. It adapts well to various body curvatures and achieves effective beam control in both planar and spherical shapes, with a lateral resolution smaller than 3 mm. The FBUTA can generate acoustic pressures up to 0.5 MPa with an excitation voltage of 36 V, making it suitable for neuromodulation applications. Additionally, it shows promise for scalable manufacturing and improved therapeutic outcomes.

Authors

Institutions

Publication Details

Published
2024-09-22
DOI
https://doi.org/10.1109/uffc-js60046.2024.10794121
Primary Topic
Ultrasound and Hyperthermia Applications
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

A Flexible Body-Conformable Ultrasound Transducer Array for Neuromodulation Applications

Huixiong Xu, Le‐Hang Guo, Chang Peng, Jiayi Zhang
Ultrasound and Hyperthermia Applications
article

A Flexible Body-Conformable Ultrasound Transducer Array for Neuromodulation Applications

Huixiong Xu, Le‐Hang Guo, Chang Peng, Jiayi Zhang
article en

Abstract

Ultrasound neuromodulation offers a noninvasive treatment for neuropathic diseases, providing exceptional spatial resolution and deeper penetration than electrical neural stimulation. However, existing ultrasound transducers face challenges in precise targeting, adjustable treatment areas, and patient comfort. This study presents a flexible body-conformable ultrasound transducer array (FBUTA) designed for precise and comfortable neuromodulation. Utilizing advanced flexible materials, the FBUTA comprises 6 × 6 elements with a center frequency of 0.67 MHz, demonstrating excellent uniformity and stability across all elements, as well as superior mechanical performance. It adapts well to various body curvatures and achieves effective beam control in both planar and spherical shapes, with a lateral resolution smaller than 3 mm. The FBUTA can generate acoustic pressures up to 0.5 MPa with an excitation voltage of 36 V, making it suitable for neuromodulation applications. Additionally, it shows promise for scalable manufacturing and improved therapeutic outcomes.

Tongji University (CN), Fudan University (CN), ShanghaiTech University (CN), Zhongshan Hospital (CN), Shanghai Tenth People's Hospital (CN)
National Natural Science Foundation of China
Affordable and clean energy
Openalex Percentile: Top 78%
Ultrasound and Hyperthermia Applications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.