Industrial validation of the PMUT ultrasonic flowmeter based on CSOI

This paper demonstrates the industrial validation of the piezoelectric micromachined ultrasonic flowmeter based on cavity silicon-on-Insulator(CSOI). The piezoelectric micromachined ultrasonic transducers(PMUTs) array was fabricated on an 8-inch CSOI wafer with unique structural layers and high scandium concentration.Through controlling the wafer-level stress variation at ±80 MPa and patterning the device layer,the great electrical characterization showed great wafer-level uniformity and yield. This implies that the device can be utilized in batch production. The reliability test conducted on PMUTs array (2.8 mm × 2.8 mm) revealed that the zero-flow offset of arbitrarily selected sensors is only 3ns and the receiving amplitude variation with temperature is within 25% witch much less than bulks.These results have a positive impact on promoting the industrialization of PMUTs.

Authors

Institutions

Publication Details

Published
2024-09-22
DOI
https://doi.org/10.1109/uffc-js60046.2024.10793727
Primary Topic
Flow Measurement and Analysis
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Industrial validation of the PMUT ultrasonic flowmeter based on CSOI

Shaokun Wang, A. Safari, Haochen Lyu, Songsong Zhang
Flow Measurement and Analysis
article

Industrial validation of the PMUT ultrasonic flowmeter based on CSOI

Shaokun Wang, A. Safari, Haochen Lyu, Songsong Zhang
article en

Abstract

This paper demonstrates the industrial validation of the piezoelectric micromachined ultrasonic flowmeter based on cavity silicon-on-Insulator(CSOI). The piezoelectric micromachined ultrasonic transducers(PMUTs) array was fabricated on an 8-inch CSOI wafer with unique structural layers and high scandium concentration.Through controlling the wafer-level stress variation at ±80 MPa and patterning the device layer,the great electrical characterization showed great wafer-level uniformity and yield. This implies that the device can be utilized in batch production. The reliability test conducted on PMUTs array (2.8 mm × 2.8 mm) revealed that the zero-flow offset of arbitrarily selected sensors is only 3ns and the receiving amplitude variation with temperature is within 25% witch much less than bulks.These results have a positive impact on promoting the industrialization of PMUTs.

Rutgers, The State University of New Jersey (US), Shanghai University (CN)
Openalex Percentile: Top 74%
Flow Measurement and Analysis
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.