Investigation of AC Poling for PZT/PZT Sol-Gel Composite

Conventionally, corona discharge poling has been used to polarize porous sol-gel composites, but there are problems with the uniformity of the polarization. In this study, we performed AC poling of sol-gel composites and compared the results with corona discharge poling. As a result, the d<inf xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">33</inf> and ultrasonic sensitivity of the sample that used AC poling were comparable to those of the samples that used corona discharge poling, and the variation in these values was small. In addition, the result of the high-temperature test showed that the devices could operate without any problems when heated to around 200°C

Authors

Institutions

Publication Details

Published
2024-09-22
DOI
https://doi.org/10.1109/uffc-js60046.2024.10793545
Citations
1
Primary Topic
Electrical Contact Performance and Analysis
Type
article
Field-Weighted Citation Impact
0.21
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Investigation of AC Poling for PZT/PZT Sol-Gel Composite

Makiko Kobayashi, Ryota Ono
1 citations
Electrical Contact Performance and Analysis
0.21
article

Investigation of AC Poling for PZT/PZT Sol-Gel Composite

Makiko Kobayashi, Ryota Ono
article en
1 citations

Abstract

Conventionally, corona discharge poling has been used to polarize porous sol-gel composites, but there are problems with the uniformity of the polarization. In this study, we performed AC poling of sol-gel composites and compared the results with corona discharge poling. As a result, the d<inf xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">33</inf> and ultrasonic sensitivity of the sample that used AC poling were comparable to those of the samples that used corona discharge poling, and the variation in these values was small. In addition, the result of the high-temperature test showed that the devices could operate without any problems when heated to around 200°C

Kumamoto University (JP)
Openalex Percentile: Top 49%
Electrical Contact Performance and Analysis
0.21
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.