Anti-reflective Microengineered Substrate for in vitro Ultrasound Neuromodulation

Poor stimulus-response correlation, caused by acoustic reflections from conventional culture substrates, poses a significant challenge in cellular mechanistic studies of ultrasound neuromodulation. Existing specialized setups that mitigate this interference have limited recording capabilities. In this study, we propose an anti-reflective microengineered substrate (ARMS) that can be incorporated into a standard in vitro platform. The substrate’s dimensions and material composition were optimized in simulation. The optimized simulated platform exhibited an 86.3% reduction in reflection amplitude on the substrate surface compared to the conventional glass substrate. Furthermore, the ARMS reduced stimulation signal distortion to a 19.2% deviation from the expected amplitude, a substantial improvement compared to the 76.4% deviation observed with glass.

Authors

Institutions

Publication Details

Published
2024-09-22
DOI
https://doi.org/10.1109/uffc-js60046.2024.10793577
Primary Topic
Ultrasound and Hyperthermia Applications
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Anti-reflective Microengineered Substrate for in vitro Ultrasound Neuromodulation

Gandhika K. Wardhana, Tiago Costa, Massimo Mastrangeli
Ultrasound and Hyperthermia Applications
article

Anti-reflective Microengineered Substrate for in vitro Ultrasound Neuromodulation

Gandhika K. Wardhana, Tiago Costa, Massimo Mastrangeli
article en

Abstract

Poor stimulus-response correlation, caused by acoustic reflections from conventional culture substrates, poses a significant challenge in cellular mechanistic studies of ultrasound neuromodulation. Existing specialized setups that mitigate this interference have limited recording capabilities. In this study, we propose an anti-reflective microengineered substrate (ARMS) that can be incorporated into a standard in vitro platform. The substrate’s dimensions and material composition were optimized in simulation. The optimized simulated platform exhibited an 86.3% reduction in reflection amplitude on the substrate surface compared to the conventional glass substrate. Furthermore, the ARMS reduced stimulation signal distortion to a 19.2% deviation from the expected amplitude, a substantial improvement compared to the 76.4% deviation observed with glass.

Delft University of Technology (NL)
Openalex Percentile: Top 78%
Ultrasound and Hyperthermia Applications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Anti-reflective Microengineered Substrate for in vitro Ultrasound Neuromodulation — Gandhika K. Wardhana, Tiago Costa, et al. · (2024) | TGRS Research Map | TGRS