A PMUT-Based Wearable Ultrasound System for Central Blood Pressure Monitoring

Central blood pressure is a more accurate indicator to various cardiovascular diseases compared to the widely used clinical measure of brachial blood pressure. Noninvasive measurement of central blood pressure via ultrasound eliminates the risk associated with arterial catheterization. However, existing ultrasound-based methods, which rely on Bramwell-Hill model, necessitate auxiliary modules or time-consuming algorithms, causing significant inconveniences and extended evaluation time. Furthermore, the high voltage requirement of pulsers presents a challenge for the systems based on conventional transducers in terms of size reduction and application in wearable devices. In response to these challenges, we have developed a compact and low-power-consumption linear probe of piezoelectric micromachined ultrasonic transducers (PMUTs) for non-invasive, real-time, and user-friendly monitoring of central blood pressure. Applying a derived model of Bramwell-Hill model, systolic and diastolic pressures of carotid artery were calculated from the real-time diameter and PWV. The accuracy and reproducibility of the system is validated on 12 subjects. The system shows considerable accuracy and reproducibility on carotid blood pressure measurement. As the system composes PMUT probe and the werable hardware design, the system demonstrates tremenondous potential toward realizing real-time wearable monitoring of central blood pressure.

Authors

Institutions

Publication Details

Published
2024-09-22
DOI
https://doi.org/10.1109/uffc-js60046.2024.10793732
Citations
4
Primary Topic
Non-Invasive Vital Sign Monitoring
Type
article
Field-Weighted Citation Impact
0.74
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

A PMUT-Based Wearable Ultrasound System for Central Blood Pressure Monitoring

Zunliang Wang, Xiaoduo Zhang, Yin Feng, Xiaoxiang Gao et al.
4 citations
Non-Invasive Vital Sign Monitoring
0.74
article

A PMUT-Based Wearable Ultrasound System for Central Blood Pressure Monitoring

Zunliang Wang, Xiaoduo Zhang, Yin Feng, Xiaoxiang Gao, Jingqi Chen, Hanzhang Liu, Hui Li, Hang Yang, Chuan Chen
article en
4 citations

Abstract

Central blood pressure is a more accurate indicator to various cardiovascular diseases compared to the widely used clinical measure of brachial blood pressure. Noninvasive measurement of central blood pressure via ultrasound eliminates the risk associated with arterial catheterization. However, existing ultrasound-based methods, which rely on Bramwell-Hill model, necessitate auxiliary modules or time-consuming algorithms, causing significant inconveniences and extended evaluation time. Furthermore, the high voltage requirement of pulsers presents a challenge for the systems based on conventional transducers in terms of size reduction and application in wearable devices. In response to these challenges, we have developed a compact and low-power-consumption linear probe of piezoelectric micromachined ultrasonic transducers (PMUTs) for non-invasive, real-time, and user-friendly monitoring of central blood pressure. Applying a derived model of Bramwell-Hill model, systolic and diastolic pressures of carotid artery were calculated from the real-time diameter and PWV. The accuracy and reproducibility of the system is validated on 12 subjects. The system shows considerable accuracy and reproducibility on carotid blood pressure measurement. As the system composes PMUT probe and the werable hardware design, the system demonstrates tremenondous potential toward realizing real-time wearable monitoring of central blood pressure.

State Key Laboratory of Digital Medical Engineering (CN), Southeast University (CN)
Good health and well-being
Openalex Percentile: Top 31%
Non-Invasive Vital Sign Monitoring
0.74
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

A PMUT-Based Wearable Ultrasound System for Central Blood Pressure Monitoring — Zunliang Wang, Xiaoduo Zhang, et al. · (2024) | TGRS Research Map | TGRS