A Spatiotemporal Correlation-Based Data Recovery Method for Improving the Performance of Electronic Noses

Issues of sensor failure, data transmission interruption, and even power interruption can result in randomly piecewise missing of detection data of online instrumentation and measurement systems, which will lead to large detection errors and even wrong decisions in real-world scenarios. It has been posed as a critical problem for electronic noses, which have been widely studied as a gas/odor measurement system, as the accuracy of identification and quantification of target gases or odors is greatly dependent on the data acquisition from the sensor array. To address this issue, a novel electronic nose data recovery method based on spatiotemporal correlation is proposed and studied in this work. Specifically, a deep gated recurrent unit (GRU)-based time-series model is devised to explore the potential time-series relationships between the missing data and the historical data. In addition, an extreme learning machine (ELM)-driven spatial correlation model is established to harness the intersensor correlations within the array. Finally, a weighted fusion of temporal and spatial correlation predictions is performed to obtain more accurate recovery data and lower gas detection errors. Experimental validation was conducted using a laboratory-built electronic nose system, which included the detection of peracetic acid concentrations at 0.5% and 0.4%. Experimental results demonstrate a significant improvement in the accuracy of gas concentration quantification when utilizing the proposed data recovery method. Compared with results obtained from random piecewise loss data, both the RMSE and MAE are reduced by at least 50%. It is proved that the proposed approach is capable of effectively recovering data missing occurring simultaneously in the array as well as continuous data missing across multiple time points.

Authors

Institutions

Publication Details

Journal
IEEE Transactions on Instrumentation and Measurement
Published
2024-12-18
DOI
https://doi.org/10.1109/tim.2024.3509546
Citations
2
Primary Topic
Advanced Chemical Sensor Technologies
Type
article
Field-Weighted Citation Impact
0.37

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

A Spatiotemporal Correlation-Based Data Recovery Method for Improving the Performance of Electronic Noses

Aixiang He, Chun-Yuan Gao, Baichuan Wang, Shasha Jiao et al.
2 citations
IEEE Transactions on Instrumentation and Measurement
Advanced Chemical Sensor Technologies
0.37
article

A Spatiotemporal Correlation-Based Data Recovery Method for Improving the Performance of Electronic Noses

Aixiang He, Chun-Yuan Gao, Baichuan Wang, Shasha Jiao, Guangfen Wei
article en
2 citations

Abstract

Issues of sensor failure, data transmission interruption, and even power interruption can result in randomly piecewise missing of detection data of online instrumentation and measurement systems, which will lead to large detection errors and even wrong decisions in real-world scenarios. It has been posed as a critical problem for electronic noses, which have been widely studied as a gas/odor measurement system, as the accuracy of identification and quantification of target gases or odors is greatly dependent on the data acquisition from the sensor array. To address this issue, a novel electronic nose data recovery method based on spatiotemporal correlation is proposed and studied in this work. Specifically, a deep gated recurrent unit (GRU)-based time-series model is devised to explore the potential time-series relationships between the missing data and the historical data. In addition, an extreme learning machine (ELM)-driven spatial correlation model is established to harness the intersensor correlations within the array. Finally, a weighted fusion of temporal and spatial correlation predictions is performed to obtain more accurate recovery data and lower gas detection errors. Experimental validation was conducted using a laboratory-built electronic nose system, which included the detection of peracetic acid concentrations at 0.5% and 0.4%. Experimental results demonstrate a significant improvement in the accuracy of gas concentration quantification when utilizing the proposed data recovery method. Compared with results obtained from random piecewise loss data, both the RMSE and MAE are reduced by at least 50%. It is proved that the proposed approach is capable of effectively recovering data missing occurring simultaneously in the array as well as continuous data missing across multiple time points.

IEEE Transactions on Instrumentation and MeasurementVol. 74
China Agricultural University (CN), Shandong Institute of Business and Technology (CN)
National Natural Science Foundation of China, Government of Shandong Province
Affordable and clean energy
Openalex Percentile: Top 41%
Advanced Chemical Sensor Technologies
0.37
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.