Study on Non-Contact Rotation Mechanism Using Single Ultrasonic Transducer : 2nd Report : Installation of Reflector

Ultrasonic motors are known as actuators that use ultrasonic vibration. Actuation force is induced though friction, which causes wear and damage on sliding parts, resulting in a shortened lifetime. Previously, an airborne non-contact rotation mechanism using ultrasonic vibration was proposed. In this mechanism, an ultrasonic transducer is fixed with its vibration surface facing upward, and a rotor with geometrically designed holes was placed on the surface. The rotor is levitated and rotated with ultrasonic vibration. Since this rotating mechanism is non-contact, a longer lifetime of the actuator can be expected. Non-contact rotation was observed, and the effect of the shape of the rotor holes on rotation was examined. In this report, a new mechanism using reflected ultrasonic wave was proposed, and the effect of the reflected wave on rotation was evaluated in expectation of improving stability and rotational performance.

Authors

Institutions

Publication Details

Published
2024-09-22
DOI
https://doi.org/10.1109/uffc-js60046.2024.10793972
Primary Topic
Engineering Applied Research
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Study on Non-Contact Rotation Mechanism Using Single Ultrasonic Transducer : 2nd Report : Installation of Reflector

Keisuke Hasegawa, Takuma Hagio, Takeshi Mizuno, Masaya TAKASAKI et al.
Engineering Applied Research
article

Study on Non-Contact Rotation Mechanism Using Single Ultrasonic Transducer : 2nd Report : Installation of Reflector

Keisuke Hasegawa, Takuma Hagio, Takeshi Mizuno, Masaya TAKASAKI, Yuji Lshino
article en

Abstract

Ultrasonic motors are known as actuators that use ultrasonic vibration. Actuation force is induced though friction, which causes wear and damage on sliding parts, resulting in a shortened lifetime. Previously, an airborne non-contact rotation mechanism using ultrasonic vibration was proposed. In this mechanism, an ultrasonic transducer is fixed with its vibration surface facing upward, and a rotor with geometrically designed holes was placed on the surface. The rotor is levitated and rotated with ultrasonic vibration. Since this rotating mechanism is non-contact, a longer lifetime of the actuator can be expected. Non-contact rotation was observed, and the effect of the shape of the rotor holes on rotation was examined. In this report, a new mechanism using reflected ultrasonic wave was proposed, and the effect of the reflected wave on rotation was evaluated in expectation of improving stability and rotational performance.

Saitama University (JP)
Affordable and clean energy
Openalex Percentile: Top 73%
Engineering Applied Research
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.