Real-time, high-frame-rate, vector Doppler ultrasound imaging by a hybrid open platform

Ultrasound high-frame-rate (HFR) Vector Doppler Imaging (VDI) offers enhanced blood flow and tissue motion dynamics visualization. However, its clinical translation is hindered by a high computational load, which prevents real-time feedback. This work aims to implement and validate a novel heterogeneous open platform with a real-time HFR VDI technique based on two oriented coordinate systems. For each TX event, the scanner’s FPGAs perform parallel beamforming on the received echoes and reconstruct two raw images, one for each differently oriented coordinate system. Subsequently, the signals are demodulated and streamed to the onboard GPU module, which extracts the axial velocity components for both oriented directions through an HFR color flow mapping technique. Finally, the algorithm reconstructs the 2D vector field in a common Cartesian coordinate system by triangulating the information from the two oriented velocity maps. The proposed method was validated using a flow phantom with a 7 mm-diameter tube, where the maximum steady flow speed ranged between 4.4 cm/s and 8.4 cm/s. Results showed that the average bias and standard deviation on the estimation of the velocity module were smaller than 20% and 22%, respectively.

Authors

Institutions

Publication Details

Published
2024-09-22
DOI
https://doi.org/10.1109/uffc-js60046.2024.10793839
Citations
4
Primary Topic
Ultrasound Imaging and Elastography
Type
article
Field-Weighted Citation Impact
1.62

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Real-time, high-frame-rate, vector Doppler ultrasound imaging by a hybrid open platform

Francesco Guidi, Damien Garcia, François Varray, Enrico Boni et al.
4 citations
Ultrasound Imaging and Elastography
1.62
article

Real-time, high-frame-rate, vector Doppler ultrasound imaging by a hybrid open platform

Francesco Guidi, Damien Garcia, François Varray, Enrico Boni, Piero Tortoli, Alessandro Ramalli, Giulio Bonciani, Adeline Bernard
article en
4 citations

Abstract

Ultrasound high-frame-rate (HFR) Vector Doppler Imaging (VDI) offers enhanced blood flow and tissue motion dynamics visualization. However, its clinical translation is hindered by a high computational load, which prevents real-time feedback. This work aims to implement and validate a novel heterogeneous open platform with a real-time HFR VDI technique based on two oriented coordinate systems. For each TX event, the scanner’s FPGAs perform parallel beamforming on the received echoes and reconstruct two raw images, one for each differently oriented coordinate system. Subsequently, the signals are demodulated and streamed to the onboard GPU module, which extracts the axial velocity components for both oriented directions through an HFR color flow mapping technique. Finally, the algorithm reconstructs the 2D vector field in a common Cartesian coordinate system by triangulating the information from the two oriented velocity maps. The proposed method was validated using a flow phantom with a 7 mm-diameter tube, where the maximum steady flow speed ranged between 4.4 cm/s and 8.4 cm/s. Results showed that the average bias and standard deviation on the estimation of the velocity module were smaller than 20% and 22%, respectively.

Université Claude Bernard Lyon 1 (FR), Centre National de la Recherche Scientifique (FR), Inserm (FR), University of Florence (IT)
Ministry of Education
Openalex Percentile: Top 15%
Ultrasound Imaging and Elastography
1.62
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Real-time, high-frame-rate, vector Doppler ultrasound imaging by a hybrid open platform — Francesco Guidi, Damien Garcia, et al. · (2024) | TGRS Research Map | TGRS