Enhancing Contrast in Circular-view Photoacoustic Computed Tomography Systems

In this study, we propose a novel method to enhance image quality in sparse circular-view photoacoustic computed tomography (PACT) systems. Traditional PACT systems rely on dense arrays of detectors to achieve high-resolution images, but they suffer from high cost and computational complexity. Our proposed method addresses these challenges by reconstructing multiple low-quality images (LQIs) from under-sampled data and using advanced signal processing techniques, including cross-correlation and the coefficient of variation (CV), to generate a stability ratio (SR) that significantly improves image quality and contrast. We evaluated the proposed method using both artery and Derenzo phantoms, with detector arrays of 1024, 512, and 256 elements. The results demonstrated that our approach effectively suppresses artifacts and enhances image quality even with a reduced number of detectors. Quantitatively, the proposed method showed substantial improvements over conventional techniques, with up to 50% reduction in background noise, a 6 dB increase in signal-to-noise ratio (SNR), and a significant enhancement in structural similarity index (SSIM). These findings suggest that the proposed method enables high-quality PACT imaging with fewer detectors, which is essential to develop a cost-effective and efficient biomedical imaging tool.

Authors

Institutions

Publication Details

Published
2024-09-22
DOI
https://doi.org/10.1109/uffc-js60046.2024.10794093
Citations
2
Primary Topic
Photoacoustic and Ultrasonic Imaging
Type
article
Field-Weighted Citation Impact
0.37
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Enhancing Contrast in Circular-view Photoacoustic Computed Tomography Systems

Soheil Hakakzadeh, Zahra Kavehvash, Mohammad Mehrmohammadi
2 citations
Photoacoustic and Ultrasonic Imaging
0.37
article

Enhancing Contrast in Circular-view Photoacoustic Computed Tomography Systems

Soheil Hakakzadeh, Zahra Kavehvash, Mohammad Mehrmohammadi
article en
2 citations

Abstract

In this study, we propose a novel method to enhance image quality in sparse circular-view photoacoustic computed tomography (PACT) systems. Traditional PACT systems rely on dense arrays of detectors to achieve high-resolution images, but they suffer from high cost and computational complexity. Our proposed method addresses these challenges by reconstructing multiple low-quality images (LQIs) from under-sampled data and using advanced signal processing techniques, including cross-correlation and the coefficient of variation (CV), to generate a stability ratio (SR) that significantly improves image quality and contrast. We evaluated the proposed method using both artery and Derenzo phantoms, with detector arrays of 1024, 512, and 256 elements. The results demonstrated that our approach effectively suppresses artifacts and enhances image quality even with a reduced number of detectors. Quantitatively, the proposed method showed substantial improvements over conventional techniques, with up to 50% reduction in background noise, a 6 dB increase in signal-to-noise ratio (SNR), and a significant enhancement in structural similarity index (SSIM). These findings suggest that the proposed method enables high-quality PACT imaging with fewer detectors, which is essential to develop a cost-effective and efficient biomedical imaging tool.

Sharif University of Technology (IR), University of Rochester Medical Center (US)
Openalex Percentile: Top 41%
Photoacoustic and Ultrasonic Imaging
0.37
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.