Design of photoacoustic modular helmet for neonatal neurocritical care

Perinatal arterial ischemic stroke (PAIS) is a form of focal vascular neurological injury that occurs during or shortly after birth. We recently proposed a modular PA helmet (PAH) system, in which multiple modules constitutes a flexible helmet to accommodate any neonatal head shape and size to provide volumetric monitoring of neonatal brain oxygen saturation. Here, optical tracking of the PAH configuration enables spatial image reconstruction. Given the large freedom in PAH configuration, it is critical to understand the implications of various design parameters in imaging quality. In this paper, we present our simulation-aided design approach using acoustic and optical simulation tools. Our design criteria are to optimize 1) signal contrast and 2) spatial resolution with different number of modules and their mean distances, and is further challenged with modular position error inevitable in modular position recognition. Results of the simulation established an acceptable error threshold for optical tracking and informed module prototype configuration and shape. The prototype based on the optimal design specifications is also demonstrated.

Authors

Institutions

Publication Details

Published
2024-09-22
DOI
https://doi.org/10.1109/uffc-js60046.2024.10793584
Primary Topic
Photoacoustic and Ultrasonic Imaging
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Design of photoacoustic modular helmet for neonatal neurocritical care

May Chen, Emad M. Boctor, Keshuai Xu, Jeeun Kang et al.
Photoacoustic and Ultrasonic Imaging
article

Design of photoacoustic modular helmet for neonatal neurocritical care

May Chen, Emad M. Boctor, Keshuai Xu, Jeeun Kang, Ananya Tandri
article en

Abstract

Perinatal arterial ischemic stroke (PAIS) is a form of focal vascular neurological injury that occurs during or shortly after birth. We recently proposed a modular PA helmet (PAH) system, in which multiple modules constitutes a flexible helmet to accommodate any neonatal head shape and size to provide volumetric monitoring of neonatal brain oxygen saturation. Here, optical tracking of the PAH configuration enables spatial image reconstruction. Given the large freedom in PAH configuration, it is critical to understand the implications of various design parameters in imaging quality. In this paper, we present our simulation-aided design approach using acoustic and optical simulation tools. Our design criteria are to optimize 1) signal contrast and 2) spatial resolution with different number of modules and their mean distances, and is further challenged with modular position error inevitable in modular position recognition. Results of the simulation established an acceptable error threshold for optical tracking and informed module prototype configuration and shape. The prototype based on the optimal design specifications is also demonstrated.

Johns Hopkins University (US), Johns Hopkins Medicine (US)
National Institute of Biomedical Imaging and Bioengineering, HORIZON EUROPE Health
Openalex Percentile: Top 78%
Photoacoustic and Ultrasonic Imaging
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Design of photoacoustic modular helmet for neonatal neurocritical care — May Chen, Emad M. Boctor, et al. · (2024) | TGRS Research Map | TGRS