3D Ultrafast ICE Image-based In-vivo Ablation Catheter Tip Detection

Intracardiac echocardiography (ICE) is the leading imaging modality for various cardiac interventions, providing real-time images of the anatomical structures and interventional tools such as ablation catheters. Image-based localization of the ablation catheter can reduce procedure time and exposure to fluoroscopy. We propose an ablation catheter tip detection framework that combines a 3D nnU-Net-based segmentation and post-processing. Our method allows us to robustly detect the ablation catheter tip. The proposed method achieved a segmentation test dice score of 0.80 and 0.78, mean tip location error of 2.1 mm and 2.1 mm, and mean tip angular error of 2.4° and 2.3°, when trained with Delay-and-Sum (DAS) and Iterative Maximum a Posteriori (IMAP) beamformed images, respectively.

Authors

Publication Details

Published
2024-09-22
DOI
https://doi.org/10.1109/uffc-js60046.2024.10793998
Primary Topic
Laser Material Processing Techniques
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

3D Ultrafast ICE Image-based In-vivo Ablation Catheter Tip Detection

Stefan Herz, Martina Casagrande, Raja Sekhar Bandaru, Stefan Wörz et al.
Laser Material Processing Techniques
article

3D Ultrafast ICE Image-based In-vivo Ablation Catheter Tip Detection

Stefan Herz, Martina Casagrande, Raja Sekhar Bandaru, Stefan Wörz, Christoph Hennersperger
article en

Abstract

Intracardiac echocardiography (ICE) is the leading imaging modality for various cardiac interventions, providing real-time images of the anatomical structures and interventional tools such as ablation catheters. Image-based localization of the ablation catheter can reduce procedure time and exposure to fluoroscopy. We propose an ablation catheter tip detection framework that combines a 3D nnU-Net-based segmentation and post-processing. Our method allows us to robustly detect the ablation catheter tip. The proposed method achieved a segmentation test dice score of 0.80 and 0.78, mean tip location error of 2.1 mm and 2.1 mm, and mean tip angular error of 2.4° and 2.3°, when trained with Delay-and-Sum (DAS) and Iterative Maximum a Posteriori (IMAP) beamformed images, respectively.

Openalex Percentile: Top 74%
Laser Material Processing Techniques
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

3D Ultrafast ICE Image-based In-vivo Ablation Catheter Tip Detection — Stefan Herz, Martina Casagrande, et al. · (2024) | TGRS Research Map | TGRS