A Graph-Based Realistic 3D Microvascular Flow Simulation for Ultrasound

This work demonstrates a microvascular ultrasound flow simulator implementing a volume-preserving static flow approximation in a microvascular graph, suitable for use with ultrasound simulation. The hypothesis is that volume-preserving particle flow enables the simulation of the microvasculature together with tissue such that the effects of echo-cancellation as seen in vivo is replicated. To enable volume-preserving flow, volumetric flow mapping of bifurcations and a full connected arterial-venous vessel coupling through the capillaries is implemented. The simulator is used together with either computer-generated microvasculature or with microvasculatures extracted from an ex-vivo segmented 3D µCT dataset from the excised kidney of a Sprague-Dawley rat, with the simulation result of the latter being visually validated against a flow image (power-Doppler) of the same rat. Simulating the blood flow together with tissue results in a flow image closely resembling one derived from real in-vivo flow data. This thus confirms that by circulating continous flow in a graph vasculature, blood-flow images of the microvasculature necessitating echo cancellation can be replicated in a simulator.

Authors

Institutions

Publication Details

Published
2024-09-22
DOI
https://doi.org/10.1109/uffc-js60046.2024.10794092
Primary Topic
Ultrasound Imaging and Elastography
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

A Graph-Based Realistic 3D Microvascular Flow Simulation for Ultrasound

Mikkel Schou, Nathalie Sarup Panduro, Anders Bjorholm Dahl, Jørgen Arendt Jensen et al.
Ultrasound Imaging and Elastography
article

A Graph-Based Realistic 3D Microvascular Flow Simulation for Ultrasound

Mikkel Schou, Nathalie Sarup Panduro, Anders Bjorholm Dahl, Jørgen Arendt Jensen, Hans Martin Kjer, Charlotte Mehlin Sørensen, Stinne Byrholdt Søgaard, L. Hansen, S. B. Andersen, Andre Ráth, Lotte de Winter
article en

Abstract

This work demonstrates a microvascular ultrasound flow simulator implementing a volume-preserving static flow approximation in a microvascular graph, suitable for use with ultrasound simulation. The hypothesis is that volume-preserving particle flow enables the simulation of the microvasculature together with tissue such that the effects of echo-cancellation as seen in vivo is replicated. To enable volume-preserving flow, volumetric flow mapping of bifurcations and a full connected arterial-venous vessel coupling through the capillaries is implemented. The simulator is used together with either computer-generated microvasculature or with microvasculatures extracted from an ex-vivo segmented 3D µCT dataset from the excised kidney of a Sprague-Dawley rat, with the simulation result of the latter being visually validated against a flow image (power-Doppler) of the same rat. Simulating the blood flow together with tissue results in a flow image closely resembling one derived from real in-vivo flow data. This thus confirms that by circulating continous flow in a graph vasculature, blood-flow images of the microvasculature necessitating echo cancellation can be replicated in a simulator.

University of Copenhagen (DK), Eindhoven University of Technology (NL), Technical University of Denmark (DK)
European Research Council
Zero hunger
Openalex Percentile: Top 60%
Ultrasound Imaging and Elastography
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

A Graph-Based Realistic 3D Microvascular Flow Simulation for Ultrasound — Mikkel Schou, Nathalie Sarup Panduro, et al. · (2024) | TGRS Research Map | TGRS