Clinical outcomes of modified left ventricular assist device driveline management

Left ventricular assist devices (LVADs) are implanted in patients with heart failure to support cardiac circulation. However, no standardized methods have been established for LVAD driveline exit site management for the prevention of infections. Therefore, this study evaluated the efficacy of modified driveline management compared with that of conventional driveline management. We retrospectively assessed the outcomes of 262 patients who underwent continuous-flow LVAD implantation between January 2005 and March 2023 at Osaka University in Japan. In conventional driveline management, an LVAD driveline penetrates the skin along the body surface and is fixed near the penetration site (n = 224). In contrast, in our modified fixation method, the LVAD driveline vertically penetrates the skin to prevent ischemia at the driveline exit site and is fixed at a distant abdominal site to prevent the movement of the driveline exit site due to body movement (n = 38). The rates of freedom from LVAD driveline infection in patients with conventional driveline management were 86, 75, and 63% at 1, 2, and 3 years after LVAD implantation, respectively. The rate of freedom from LVAD driveline infection in patients managed by the modified fixation method was 91% at 1, 2, as well as 3 years after LVAD implantation. The freedom rates from LVAD driveline infection in the patients with modified fixation method was lower than in the patients with the conventional method (p = 0.04). Our study revealed that the modified fixation method may offer the possibility for preventing LVAD driveline infection.

Authors

Institutions

Publication Details

Journal
Journal of Artificial Organs
Published
2024-12-18
DOI
https://doi.org/10.1007/s10047-024-01482-8
Citations
2
Primary Topic
Mechanical Circulatory Support Devices
Type
article
Field-Weighted Citation Impact
0.37

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Clinical outcomes of modified left ventricular assist device driveline management

Shunsuke Saito, Shusuke Imaoka, Ai Kawamura, Daisuke Yoshioka et al.
2 citations
Journal of Artificial Organs
Mechanical Circulatory Support Devices
0.37
article

Clinical outcomes of modified left ventricular assist device driveline management

Shunsuke Saito, Shusuke Imaoka, Ai Kawamura, Daisuke Yoshioka, T Kawamura, Yusuke Misumi, Ryohei Matsuura, Noriyuki Kashiyama, Koichi Toda, Shigeru Miyagawa
article en
2 citations

Abstract

Left ventricular assist devices (LVADs) are implanted in patients with heart failure to support cardiac circulation. However, no standardized methods have been established for LVAD driveline exit site management for the prevention of infections. Therefore, this study evaluated the efficacy of modified driveline management compared with that of conventional driveline management. We retrospectively assessed the outcomes of 262 patients who underwent continuous-flow LVAD implantation between January 2005 and March 2023 at Osaka University in Japan. In conventional driveline management, an LVAD driveline penetrates the skin along the body surface and is fixed near the penetration site (n = 224). In contrast, in our modified fixation method, the LVAD driveline vertically penetrates the skin to prevent ischemia at the driveline exit site and is fixed at a distant abdominal site to prevent the movement of the driveline exit site due to body movement (n = 38). The rates of freedom from LVAD driveline infection in patients with conventional driveline management were 86, 75, and 63% at 1, 2, and 3 years after LVAD implantation, respectively. The rate of freedom from LVAD driveline infection in patients managed by the modified fixation method was 91% at 1, 2, as well as 3 years after LVAD implantation. The freedom rates from LVAD driveline infection in the patients with modified fixation method was lower than in the patients with the conventional method (p = 0.04). Our study revealed that the modified fixation method may offer the possibility for preventing LVAD driveline infection.

Journal of Artificial OrgansVol. 28(2)
Fukui CardioVascular Center (JP), Social Insurance Saitama Chuo Hospital (JP), Dokkyo Medical University (JP), The University of Osaka (JP)
Osaka University
Peace, Justice and strong institutions
Openalex Percentile: Top 41%
Mechanical Circulatory Support Devices
0.37
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.