Novel colorimetric-electrochemical methods for selective identification and quantification of Scopolamine in forensic analysis using screen-printed graphite electrodes and Dragendorff reagent

In forensic investigations, the detection of Scopolamine, popularly known as Burundanga or Devil’s Breath, is of significant interest due to its potential involvement in cases of attempted murder or suicide. Currently, no efficient screening methods exist for Scopolamine detection in such forensic contexts. This study presents a novel method combining screen-printed graphite electrodes (SPGE) with square-wave voltammetry (electrochemical step) and Dragendorff reagent (colorimetric step) to detect Scopolamine in drinks (gin, tonic water, whisky, and energy drinks) and biological samples (urine, saliva, and vitreous humor). The method provides two distinct analytical responses: a visible color change (from orange to yellow) via the colorimetric reaction, and the electrochemical behavior of Scopolamine in both anodic and cathodic scans, ensuring robust and accurate identification. For the first time, the electrochemical behavior of both redox processes of Scopolamine is investigated. The proposed method demonstrated a wide linear range (0.025-0.225 mg mL −1 for the oxidation and 0.025–0.175 mg mL⁻¹ for the reduction process) with a low limit of detection of 5.0 μg mL −1 , making it suitable for forensic applications. Stability of the electrochemical response was studied with SPGE showing relative standard deviations (RSD) of less than 3 % for E p and I p across multiple electrodes (N = 3). Interference studies confirmed the method's high selectivity for Scopolamine detection. Additionally, Scopolamine was successfully identified in both beverage and biological samples with recoveries near 100 %, indicating the absence of matrix effects. The methodology using both electrochemical with a colorimetric approach presents a promising, rapid, and selective screening method for Scopolamine detection in forensic scenarios. • The method combines electrochemical and colorimetric detection for scopolamine screening. • First study of both Scopolamine oxidation and reduction processes for forensic analysis. • Fast and selective screening of Scopolamine in forensic investigations using screen-printed graphite electrodes (SPGE). • Scopolamine detection shows distinct redox behavior on SPGE. • Colorimetric-electrochemical method detects Scopolamine in forensic samples using SPGE

Authors

Institutions

Publication Details

Journal
Sensors and Actuators B Chemical
Published
2024-12-18
DOI
https://doi.org/10.1016/j.snb.2024.137131
Citations
5
Primary Topic
Electrochemical sensors and biosensors
Type
article
Field-Weighted Citation Impact
1.04
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Novel colorimetric-electrochemical methods for selective identification and quantification of Scopolamine in forensic analysis using screen-printed graphite electrodes and Dragendorff reagent

Craig E. Banks, Larissa M.A. Melo, Rodrigo Moreira Verly, Wallans Torres Pio dos Santos et al.
5 citations
Sensors and Actuators B Chemical
Electrochemical sensors and biosensors
1.04
article

Novel colorimetric-electrochemical methods for selective identification and quantification of Scopolamine in forensic analysis using screen-printed graphite electrodes and Dragendorff reagent

Craig E. Banks, Larissa M.A. Melo, Rodrigo Moreira Verly, Wallans Torres Pio dos Santos, Robert D. Crapnell, Elena Bernalte, Rodrigo A.A. Muñoz, Ana C.M. Oliveira
article en
5 citations

Abstract

In forensic investigations, the detection of Scopolamine, popularly known as Burundanga or Devil’s Breath, is of significant interest due to its potential involvement in cases of attempted murder or suicide. Currently, no efficient screening methods exist for Scopolamine detection in such forensic contexts. This study presents a novel method combining screen-printed graphite electrodes (SPGE) with square-wave voltammetry (electrochemical step) and Dragendorff reagent (colorimetric step) to detect Scopolamine in drinks (gin, tonic water, whisky, and energy drinks) and biological samples (urine, saliva, and vitreous humor). The method provides two distinct analytical responses: a visible color change (from orange to yellow) via the colorimetric reaction, and the electrochemical behavior of Scopolamine in both anodic and cathodic scans, ensuring robust and accurate identification. For the first time, the electrochemical behavior of both redox processes of Scopolamine is investigated. The proposed method demonstrated a wide linear range (0.025-0.225 mg mL −1 for the oxidation and 0.025–0.175 mg mL⁻¹ for the reduction process) with a low limit of detection of 5.0 μg mL −1 , making it suitable for forensic applications. Stability of the electrochemical response was studied with SPGE showing relative standard deviations (RSD) of less than 3 % for E p and I p across multiple electrodes (N = 3). Interference studies confirmed the method's high selectivity for Scopolamine detection. Additionally, Scopolamine was successfully identified in both beverage and biological samples with recoveries near 100 %, indicating the absence of matrix effects. The methodology using both electrochemical with a colorimetric approach presents a promising, rapid, and selective screening method for Scopolamine detection in forensic scenarios. • The method combines electrochemical and colorimetric detection for scopolamine screening. • First study of both Scopolamine oxidation and reduction processes for forensic analysis. • Fast and selective screening of Scopolamine in forensic investigations using screen-printed graphite electrodes (SPGE). • Scopolamine detection shows distinct redox behavior on SPGE. • Colorimetric-electrochemical method detects Scopolamine in forensic samples using SPGE

Sensors and Actuators B ChemicalVol. 427
Manchester Metropolitan University (GB), Universidade Federal dos Vales do Jequitinhonha e Mucuri (BR), Universidade Federal de Uberlândia (BR)
Zero hunger
Openalex Percentile: Top 22%
Electrochemical sensors and biosensors
1.04
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.