Portable Amperometric Biosensor Enhanced with Enzyme-Ternary Nanocomposites for Prostate Cancer Biomarker Detection

Enzyme-based portable amperometric biosensors are precise and low-cost medical devices used for rapid cancer biomarker screening. Sarcosine (Sar) is an ideal biomarker for prostate cancer (PCa). Because human serum and urine contain complex interfering substances that can directly oxidize at the electrode surface, rapid Sar screening biosensors are relatively challenging and have rarely been reported. Therefore, highly sensitive and selective amperometric biosensors that enable real-time measurements within <1.0 min are needed. To achieve this, a chitosan-polyaniline polymer nanocomposite (CS-PANI NC), a carrier for dispersing mesoporous carbon (MC), was synthesized and modified on a screen-printed carbon electrode (SPCE) to detect hydrogen peroxide (H<sub>2</sub>O<sub>2</sub>). The sarcosine oxidase (SOx) enzyme-immobilized CS-PANI-MC-2 ternary NCs were referred to as supramolecular architectures (SMAs). The excellent electron transfer ability of the SMA-modified SPCE (SMA/SPCE) sensor enabled highly sensitive H<sub>2</sub>O<sub>2</sub> detection for immediate trace Sar biomarker detection. Therefore, the system included an SMA/SPCE coupled to a portable potentiostat linked to a smartphone for data acquisition. The high catalytic activity, porous architecture, and sufficient biocompatibility of CS-PANI-MC ternary NCs enabled bioactivity retention and immobilized SOx stability. The fabricated biosensor exhibited a detection limit of 0.077 μM and sensitivity of 8.09 μA mM<sup>-1</sup> cm<sup>-2</sup> toward Sar, demonstrating great potential for use in rapid PCa screening.

Authors

Institutions

Publication Details

Journal
Biosensors
Published
2024-12-18
DOI
https://doi.org/10.3390/bios14120623
Citations
27
Primary Topic
Electrochemical sensors and biosensors
Type
article
Field-Weighted Citation Impact
5.63

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Portable Amperometric Biosensor Enhanced with Enzyme-Ternary Nanocomposites for Prostate Cancer Biomarker Detection

Sivaguru Jayaraman, Chang‐Seok Kim, Thenmozhi Rajarathinam, Seung‐Cheol Chang et al.
27 citations
Biosensors
Electrochemical sensors and biosensors
5.63
article

Portable Amperometric Biosensor Enhanced with Enzyme-Ternary Nanocomposites for Prostate Cancer Biomarker Detection

Sivaguru Jayaraman, Chang‐Seok Kim, Thenmozhi Rajarathinam, Seung‐Cheol Chang, Jaewon Lee
article en
27 citations

Abstract

Enzyme-based portable amperometric biosensors are precise and low-cost medical devices used for rapid cancer biomarker screening. Sarcosine (Sar) is an ideal biomarker for prostate cancer (PCa). Because human serum and urine contain complex interfering substances that can directly oxidize at the electrode surface, rapid Sar screening biosensors are relatively challenging and have rarely been reported. Therefore, highly sensitive and selective amperometric biosensors that enable real-time measurements within <1.0 min are needed. To achieve this, a chitosan-polyaniline polymer nanocomposite (CS-PANI NC), a carrier for dispersing mesoporous carbon (MC), was synthesized and modified on a screen-printed carbon electrode (SPCE) to detect hydrogen peroxide (H<sub>2</sub>O<sub>2</sub>). The sarcosine oxidase (SOx) enzyme-immobilized CS-PANI-MC-2 ternary NCs were referred to as supramolecular architectures (SMAs). The excellent electron transfer ability of the SMA-modified SPCE (SMA/SPCE) sensor enabled highly sensitive H<sub>2</sub>O<sub>2</sub> detection for immediate trace Sar biomarker detection. Therefore, the system included an SMA/SPCE coupled to a portable potentiostat linked to a smartphone for data acquisition. The high catalytic activity, porous architecture, and sufficient biocompatibility of CS-PANI-MC ternary NCs enabled bioactivity retention and immobilized SOx stability. The fabricated biosensor exhibited a detection limit of 0.077 μM and sensitivity of 8.09 μA mM<sup>-1</sup> cm<sup>-2</sup> toward Sar, demonstrating great potential for use in rapid PCa screening.

BiosensorsVol. 14(12)
Pusan National University (KR)
Korea Institute for Advancement of Technology, National Research Foundation of Korea
Openalex Percentile: Top 3%
Electrochemical sensors and biosensors
5.63
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.