A Degradation Model of Electrical Contact Performance for Copper Alloy Contacts with Tin Coatings Under Power Current-Carrying Fretting Conditions

The fretting degradation of coating materials is complicated when the Joule heating effect of the load current is non-negligible. In this work, the fretting degradation behavior of tin-coated copper alloy contacts was examined across the current range from 5 A to 30 A and the fretting amplitude range from 200 μm to 400 μm. The uniform degradation process and associated mechanisms, including the wear-dominated stage, softening-dominated stage, and oxidation-dominated stage were recognized and interpreted explicitly. An innovative fusion model for the degradation of electrical contact performance, data-driven and based on physics mechanism, was proposed. The contact voltage was selected as the characterization variable and pre-processed by the threshold-crossing filter method and the Levenberg–Marquardt algorithm. The optimal degradation model, considering the coupled effects of current and fretting amplitude, was presented with the use of the support vector regression method. Finally, the prediction accuracy of the model was validated by experiment results.

Authors

Institutions

Publication Details

Journal
Coatings
Published
2024-12-18
DOI
https://doi.org/10.3390/coatings14121587
Citations
2
Primary Topic
Electrical Contact Performance and Analysis
Type
article
Field-Weighted Citation Impact
0.43

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

A Degradation Model of Electrical Contact Performance for Copper Alloy Contacts with Tin Coatings Under Power Current-Carrying Fretting Conditions

Wanbin Ren, Yuan Meng, Chao Zhang
2 citations
Coatings
Electrical Contact Performance and Analysis
0.43
article

A Degradation Model of Electrical Contact Performance for Copper Alloy Contacts with Tin Coatings Under Power Current-Carrying Fretting Conditions

Wanbin Ren, Yuan Meng, Chao Zhang
article en
2 citations

Abstract

The fretting degradation of coating materials is complicated when the Joule heating effect of the load current is non-negligible. In this work, the fretting degradation behavior of tin-coated copper alloy contacts was examined across the current range from 5 A to 30 A and the fretting amplitude range from 200 μm to 400 μm. The uniform degradation process and associated mechanisms, including the wear-dominated stage, softening-dominated stage, and oxidation-dominated stage were recognized and interpreted explicitly. An innovative fusion model for the degradation of electrical contact performance, data-driven and based on physics mechanism, was proposed. The contact voltage was selected as the characterization variable and pre-processed by the threshold-crossing filter method and the Levenberg–Marquardt algorithm. The optimal degradation model, considering the coupled effects of current and fretting amplitude, was presented with the use of the support vector regression method. Finally, the prediction accuracy of the model was validated by experiment results.

CoatingsVol. 14(12)
Harbin Institute of Technology (CN)
National Natural Science Foundation of China, China Postdoctoral Science Foundation
Openalex Percentile: Top 40%
Electrical Contact Performance and Analysis
0.43
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

A Degradation Model of Electrical Contact Performance for Copper Alloy Contacts with Tin Coatings Under Power Current-Carrying Fretting Conditions — Wanbin Ren, Yuan Meng, et al. · Coatings (2024) | TGRS Research Map | TGRS