Coherently averaged optical frequency comb spectroscopy with a single electro-optic modulator

We present a new, to the best of our knowledge, approach for self-heterodyne optical frequency comb (OFC) spectroscopy in which a single Mach-Zehnder modulator is utilized to generate both an optical frequency comb and a frequency-shifted local oscillator. This method allows for coherent, time-domain averaging to be performed without the need for feedback mechanisms or software corrections. As an initial demonstration, we have measured acetylene rovibrational transition frequencies with coherently averaged comb spectra. Spectra averaged for less than 10 s yielded standard fit uncertainties for transition frequencies of less than 150 kHz, with deviations from literature values under 1.1 MHz, limited by pressure uncertainty. This approach has important implications for high-resolution spectroscopy, trace gas detection, and on-chip integration of electro-optic frequency combs.

Authors

Institutions

Publication Details

Journal
Optics Letters
Published
2024-12-18
DOI
https://doi.org/10.1364/ol.544905
Primary Topic
Advanced Fiber Laser Technologies
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Coherently averaged optical frequency comb spectroscopy with a single electro-optic modulator

David A. Long, Joseph Hodges, Sean M. Bresler, Vladimir Aksyuk et al.
Optics Letters
Advanced Fiber Laser Technologies
article

Coherently averaged optical frequency comb spectroscopy with a single electro-optic modulator

David A. Long, Joseph Hodges, Sean M. Bresler, Vladimir Aksyuk, Kyunghun Han, Thomas W. LeBrun, Zachary Reed
article en

Abstract

We present a new, to the best of our knowledge, approach for self-heterodyne optical frequency comb (OFC) spectroscopy in which a single Mach-Zehnder modulator is utilized to generate both an optical frequency comb and a frequency-shifted local oscillator. This method allows for coherent, time-domain averaging to be performed without the need for feedback mechanisms or software corrections. As an initial demonstration, we have measured acetylene rovibrational transition frequencies with coherently averaged comb spectra. Spectra averaged for less than 10 s yielded standard fit uncertainties for transition frequencies of less than 150 kHz, with deviations from literature values under 1.1 MHz, limited by pressure uncertainty. This approach has important implications for high-resolution spectroscopy, trace gas detection, and on-chip integration of electro-optic frequency combs.

Optics LettersVol. 50(2)
Theiss Research (US), University of Maryland, College Park (US)
Affordable and clean energy
Openalex Percentile: Top 79%
Advanced Fiber Laser Technologies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.