Cu- and Ag-mediated inactivation of <i>L. pneumophila</i> in bench- and pilot-scale drinking water systems

<i>Legionella pneumophila</i> (Lp) is an opportunistic drinking water pathogen that can cause infections through the inhalation of Lp-containing aerosols and can occur in premise plumbing systems. In this work, the use of copper (Cu) and silver (Ag) ions was evaluated at the bench and pilot scale to determine (i) the effective independent concentrations of copper and silver that are efficacious in inactivating Lp, (ii) the impact of various water quality parameters on the efficaciousness of copper and silver ions, and (iii) the effectiveness and practicality of using dissociation to produce ions at the pilot scale. At the bench scale, it was determined that 0.3 ppm and 0.03 ppm of Cu and Ag, respectively, achieved 6-log inactivation of Lp in 5 h in experimental buffer. But, in dechlorinated filter-sterilized tap water, the same concentrations of Cu were not effective, and the effectiveness of Ag was slower. pH and dissolved inorganic carbon content were found to be important parameters in determining if the use of Cu and Ag ions is appropriate. At the pilot scale, dissociation was successfully used to produce Cu and Ag ions. Target levels of ions were met at the pilot scale but were difficult to achieve, and no impact was observed on Lp concentrations. Results from this study suggest that there are important caveats in the application of this technology when applied in a drinking water matrix and prior understanding of a system's water chemistry may be important to determine the effectiveness of Lp disinfection using Cu and Ag.IMPORTANCEThis work sheds light on the effectiveness of using Cu and Ag ions to inactivate (or kill) <i>Legionella pneumophila. Legionella</i> is an opportunistic drinking water pathogen of public health concern. This work demonstrates that there are important caveats in the application of using Cu and Ag ions to inactivate <i>Legionella pneumophila</i>.

Authors

Institutions

Publication Details

Journal
Applied and Environmental Microbiology
Published
2024-12-18
DOI
https://doi.org/10.1128/aem.01073-24
Primary Topic
Water Treatment and Disinfection
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Cu- and Ag-mediated inactivation of L. pneumophila in bench- and pilot-scale drinking water systems

Chelsea L. Hintz, Brian J. Morris, Helen Y. Buse, Nicole Sojda et al.
Applied and Environmental Microbiology
Water Treatment and Disinfection
article

Cu- and Ag-mediated inactivation of L. pneumophila in bench- and pilot-scale drinking water systems

Chelsea L. Hintz, Brian J. Morris, Helen Y. Buse, Nicole Sojda, S. C. Witt
article en

Abstract

<i>Legionella pneumophila</i> (Lp) is an opportunistic drinking water pathogen that can cause infections through the inhalation of Lp-containing aerosols and can occur in premise plumbing systems. In this work, the use of copper (Cu) and silver (Ag) ions was evaluated at the bench and pilot scale to determine (i) the effective independent concentrations of copper and silver that are efficacious in inactivating Lp, (ii) the impact of various water quality parameters on the efficaciousness of copper and silver ions, and (iii) the effectiveness and practicality of using dissociation to produce ions at the pilot scale. At the bench scale, it was determined that 0.3 ppm and 0.03 ppm of Cu and Ag, respectively, achieved 6-log inactivation of Lp in 5 h in experimental buffer. But, in dechlorinated filter-sterilized tap water, the same concentrations of Cu were not effective, and the effectiveness of Ag was slower. pH and dissolved inorganic carbon content were found to be important parameters in determining if the use of Cu and Ag ions is appropriate. At the pilot scale, dissociation was successfully used to produce Cu and Ag ions. Target levels of ions were met at the pilot scale but were difficult to achieve, and no impact was observed on Lp concentrations. Results from this study suggest that there are important caveats in the application of this technology when applied in a drinking water matrix and prior understanding of a system's water chemistry may be important to determine the effectiveness of Lp disinfection using Cu and Ag.IMPORTANCEThis work sheds light on the effectiveness of using Cu and Ag ions to inactivate (or kill) <i>Legionella pneumophila. Legionella</i> is an opportunistic drinking water pathogen of public health concern. This work demonstrates that there are important caveats in the application of using Cu and Ag ions to inactivate <i>Legionella pneumophila</i>.

Applied and Environmental MicrobiologyVol. 91(1)
Environmental Protection Agency (US), Ohio Environmental Protection Agency (US), Environmental Protection Agency (GH), Applied Technical Services (United States) (US)
U.S. Environmental Protection Agency, Office of Research and Development
Clean water and sanitation
Openalex Percentile: Top 67%
Water Treatment and Disinfection
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.